Positive correlation between the proximal femur Hounsfield units from routine CT and DXA results

Author:

Ye Kaifeng123,Xing Yong123,Zou Da123,Zhou Fang123,Zhang Zhishan123,Du Guohong123,Tian Yun123ORCID

Affiliation:

1. Department of Orthopaedics Peking University Third Hospital Beijing China

2. Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education Peking University Third Hospital Beijing China

3. Beijing Key Laboratory of Spinal Disease Research Peking University Third Hospital Beijing China

Abstract

AbstractTo determinate the correlation between the proximal femur Hounsfield unit (HU) value and dual‐energy X‐ray absorptiometry (DXA) results, and to identify its feasibility for opportunistic screening osteoporosis. A total of 680 patients underwent computed tomography (CT) containing proximal femur and DXA test within 6 months between 2010 and 2020 in our hospital. The CT HU value of four axial slices of the proximal femur were measured. The measurements were compared with the DXA results by Pearson correlation coefficient. Receiver operator characteristic curve were generated to identify the best cutoff for diagnosing osteoporosis. These 680 consecutive patients included 165 male and 515 female; the average age was 63.66 ± 11.36 years old, the mean interval time between two examinations was 45.43 days. The most representative CT HU value measurement was the 5‐mm slice measurement. The average CT HU value was 59.3 ± 36.5 HU, and the differences among the three DXA defined bone mineral density (BMD) categories were significant (all p < 0.001). The Pearson correlation analysis showed that the proximal femur CT values had strong positive correlation with femoral neck T‐score, femoral neck BMD and total hip BMD (r = 0.777, r = 0.748, r = 0.746, respectively; all p < 0.001). The area under the curve for CT value for diagnosing osteoporosis was 0.893 (p < 0.001), the best cutoff was 67 HU with 84% sensitivity, 80% specificity, 92% positive predictive value and 65% negative predictive value. Proximal femur CT values had good positive correlation with DXA results, which could be used to opportunistic screening for potential osteoporosis patient.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3