Abstract

AbstractBackgroundDosimetry software tools developed for Radiopharmaceutical Therapy, such as OLINDA/EXM or IDAC‐Dose, account only for radiation dose to organs from radiopharmaceutical taken up in other organs.PurposeThe aim of this study is to present a methodology, that can be applied to any voxelised computational model, able to account for cross‐dose to organs from tumors of any shape and number enclosed within an organ.MethodsA Geant4 application using hybrid analytical/voxelised geometries has been developed as an extension to the ICRP110_HumanPhantom Geant4 advanced example and validated against ICRP publication 133. In this new Geant4 application, tumors are defined using the Geant4 Parallel Geometry functionality, which allows the co‐existence of two independent geometries in the same Monte Carlo simulation. The methodology was validated by estimating total dose to healthy tissue from 90Y and from 177Lu distributed within tumors of various sizes localized within the liver of the ICRP110 adult male phantom.ResultsAgreement of the Geant4 application with ICRP133 was within 5% when masses were adjusted for blood content. Total dose to healthy liver and to tumors was found to agree within 1% when compared to the ground truth.ConclusionsThe methodology presented in this work can be extended to investigate total dose to healthy tissue from systemic uptake of radiopharmaceuticals in tumors of different sizes using any voxelised computational dosimetric model.

Publisher

Wiley

Subject

General Medicine

Reference15 articles.

1. KunosCA CapalaJ National Cancer Institute Programmatic Collaboration for Investigational Radiopharmaceuti Cals.2018.

2. GATE: a simulation toolkit for PET and SPECT

3. OLINDA/EXM: the second‐generation personal computer software for internal dose assessment in nuclear medicine;Stabin MG;J Nucl Med,2005

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3