Ultra‐low dose CT scanning for PET/CT

Author:

Mostafapour Samaneh1,Greuter Marcel2,van Snick Johannes H.1,Brouwers Adrienne H.1,Dierckx Rudi A. J. O.1,van Sluis Joyce1,Lammertsma Adriaan A.1,Tsoumpas Charalampos1

Affiliation:

1. Nuclear Medicine and Molecular Imaging University of Groningen University Medical Center Groningen Groningen The Netherlands

2. Department of Radiology University of Groningen University Medical Center Groningen Groningen The Netherlands

Abstract

AbstractBackgroundThe use of computed tomography (CT) for attenuation correction (AC) in whole‐body PET/CT can result in a significant contribution to radiation exposure. This can become a limiting factor for reducing considerably the overall radiation exposure of the patient when using the new long axial field of view (LAFOV) PET scanners. However, recent CT technology have introduced features such as the tin (Sn) filter, which can substantially reduce the CT radiation dose.PurposeThe purpose of this study was to investigate the ultra‐low dose CT for attenuation correction using the Sn filter together with other dose reduction options such as tube current (mAs) reduction. We explore the impact of dose reduction in the context of AC‐CT and how it affects PET image quality.MethodsThe study evaluated a range of ultra‐low dose CT protocols using five physical phantoms that represented a broad collection of tissue electron densities. A long axial field of view (LAFOV) PET/CT scanner was used to scan all phantoms, applying various CT dose reduction parameters such as reducing tube current (mAs), increasing the pitch value, and applying the Sn filter. The effective dose resulting from the CT scans was determined using the CTDIVol reported by the scanner. Several voxel‐based and volumes of interest (VOI)‐based comparisons were performed to compare the ultra‐low dose CT images, the generated attenuation maps, and corresponding PET images against those images acquired with the standard low dose CT protocol. Finally, two patient datasets were acquired using one of the suggested ultra‐low dose CT settings.ResultsBy incorporating the Sn filter and adjusting mAs to the lowest available value, the radiation dose in CT images of PBU‐60 phantom was significantly reduced; resulting in an effective dose of nearly 2% compared to the routine low dose CT protocols currently in clinical use. The assessment of PET images using VOI and voxel‐based comparisons indicated relative differences (RD%) of under 6% for mean activity concentration (AC) in the torso phantom and patient dataset and under 8% for a source point in the CIRS phantom. The maximum RD% value of AC was 14% for the point source in the CIRS phantom. Increasing the tube current from 6 mAs to 30 mAs in patients with high BMI, or with arms down, can suppress the photon starvation artifact, whilst still preserving a dose reduction of 90%.ConclusionsIntroducing a Sn filter in CT imaging lowers radiation dose by more than 90%. This reduction has minimal effect on PET image quantification at least for patients without Body Mass Index (BMI) higher than 30. Notably, this study results need validation using a larger clinical PET/CT dataset in the future, including patients with higher BMI.

Publisher

Wiley

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3