Computational fluid dynamics‐based virtual angiograms for the detection of flow stagnation in intracranial aneurysms

Author:

Hadad Sara1,Karnam Yogesh1,Mut Fernando1ORCID,Lohner Rainald2ORCID,Robertson Anne M.3ORCID,Kaneko Naoki4,Cebral Juan R.1

Affiliation:

1. Department of Bioengineering George Mason University Fairfax Virginia USA

2. Center for Computational Fluid Dynamics, College of Science George Mason University Fairfax Virginia USA

3. Department of Mechanical Engineering and Material Science University of Pittsburgh Pittsburgh Pennsylvania USA

4. Department of Interventional Neuroradiology University of California Los Angeles Los Angeles California USA

Abstract

AbstractThe goal of this study was to test if CFD‐based virtual angiograms could be used to automatically discriminate between intracranial aneurysms (IAs) with and without flow stagnation. Time density curves (TDC) were extracted from patient digital subtraction angiography (DSA) image sequences by computing the average gray level intensity inside the aneurysm region and used to define injection profiles for each subject. Subject‐specific 3D models were reconstructed from 3D rotational angiography (3DRA) and computational fluid dynamics (CFD) simulations were performed to simulate the blood flow inside IAs. Transport equations were solved numerically to simulate the dynamics of contrast injection into the parent arteries and IAs and then the contrast retention time (RET) was calculated. The importance of gravitational pooling of contrast agent within the aneurysm was evaluated by modeling contrast agent and blood as a mixture of two fluids with different densities and viscosities. Virtual angiograms can reproduce DSA sequences if the correct injection profile is used. RET can identify aneurysms with significant flow stagnation even when the injection profile is not known. Using a small sample of 14 IAs of which seven were previously classified as having flow stagnation, it was found that a threshold RET value of 0.46 s can successfully identify flow stagnation. CFD‐based prediction of stagnation was in more than 90% agreement with independent visual DSA assessment of stagnation in a second sample of 34 IAs. While gravitational pooling prolonged contrast retention time it did not affect the predictive capabilities of RET. CFD‐based virtual angiograms can detect flow stagnation in IAs and can be used to automatically identify aneurysms with flow stagnation even without including gravitational effects on contrast agents.

Funder

National Institutes of Health

Publisher

Wiley

Subject

Applied Mathematics,Computational Theory and Mathematics,Molecular Biology,Modeling and Simulation,Biomedical Engineering,Software