Novel RP‐HPLC method for estimation of a newly developed combination of tizanidine and etoricoxib in rat plasma: Eight criteria for greens evaluation

Author:

Assirey Eman A.1ORCID,Ahmed Hoda A.23ORCID,AL‐Faze Rawan1ORCID,Amin M. S.14ORCID,Mahgoub Samar M.5,Abo El‐Ela Fatma I.6,Mohamed Mahmoud A.7ORCID

Affiliation:

1. Department of Chemistry, College of Science Taibah University, Al‐Madinah Al‐Munawarah Madinah Saudi Arabia

2. Chemistry Department, Faculty of Science at Yanbu Taibah University Yanbu Saudi Arabia

3. Department of Chemistry, Faculty of Science Cairo University Giza Egypt

4. Chemistry Department, Faculty of Science Ain Shams University Cairo Egypt

5. Materials Science and Nanotechnology Department, Faculty of Postgraduate Studies for Advanced Sciences Beni‐Suef University Beni‐Suef Egypt

6. Department of Pharmacology, Faculty of Veterinary Medicine Beni‐Suef University Beni‐Suef Egypt

7. Hikma Pharmaceutical Company Beni‐Suef Egypt

Abstract

AbstractA novel environmentally friendly reversed‐phase high‐performance liquid chromatography (RP‐HPLC) method has been effectively validated for simultaneously measuring a prospective conjunction of tizanidine (TIZ) and etoricoxib (ETC), the combined medicine, in rat plasma. The technique employs diclofenac potassium as the internal standard, guaranteeing dependable and precise outcomes. This study aimed to assess the impact of the suggested combination therapy on treating inflammation resulting from rheumatoid arthritis (RA) in a rat model. The procedure was performed using an Agilent series 1200 model HPLC apparatus. The chromatographic conditions consist of isocratic elution mode, C18 column with dimensions of 150 mm × 4.6 mm × 5 µm, flow rate of 1.5 mL/min, wavelength of 230 nm, temperature of 50°C, and injection volume of 10 µL. The elution was performed using a mobile phase consisting of a phosphate buffer with a pH of 3.5 and acetonitrile in a ratio of 80:20 v/v. Calibration curves were conducted for TIZ and ETC within the 1–50 µg/mL range, demonstrating linear trends with R2 values over 0.999. The effectiveness and eco‐friendliness of the proposed method were evaluated using eight separate environmentally conscious metrics. The addition of TIZ and ETC to arthritic rodents amplified these effects significantly. Furthermore, TIZ and ETC significantly reduced serum levels in arthritic rodents, and safety investigations revealed normal complete blood count, liver, and renal functions. TIZ and ETC appear to have antiarthritic, anti‐inflammatory, and safe combinations, making them viable future treatment options for RA that are also safe and efficacious. Following validation by United States Food and Drug Administration (US‐FDA) rules, all goods met the criteria.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3