Multi‐echo single‐shot spectroscopy combined with simultaneous 2D model fitting for fast and accurate measurement of metabolite‐specific concentrations and T2 relaxation times

Author:

Rizzo Rudy1234ORCID,Kreis Roland123ORCID

Affiliation:

1. MR Methodology, Department for Diagnostic and Interventional Neuroradiology University of Bern Bern Switzerland

2. Department for Biomedical Research University of Bern Bern Switzerland

3. Translational Imaging Center (TIC) Swiss Institute for Translational and Entrepreneurial Medicine (sitem‐insel) Bern Switzerland

4. Graduate School for Cellular and Biomedical Sciences University of Bern Bern Switzerland

Abstract

The purpose of the current study was to develop a novel single‐voxel MR spectroscopy acquisition scheme to simultaneously determine metabolite‐specific concentrations and transverse relaxation times within realistic clinical scan times. Partly truncated multi‐TE data are acquired as an echo train in a single acquisition (multi‐echo single‐shot [MESS]). A 2D multiparametric model fitting approach combines truncated, low‐resolved short TE data with fully sampled, highly resolved, longer TE data to yield concentration and T2 estimates for major brain metabolites simultaneously. Cramer–Rao lower bounds (CRLB) are used as a measure of performance. The novel scheme was compared with traditional multi‐echo multi‐shot methods. In silico, in vitro, and in vivo experiments support the findings. MESS schemes, requiring only 2 min 12 s for the acquisition of three echo times, provide valid concentration and relaxation estimates for multiple metabolites and outperform traditional methods for simultaneous determinations of metabolite‐specific T2s and concentrations, with improvements ranging from 5% to 30% for T2s and from 10% to 50% for concentrations. However, substantial unsuppressed residual water signals may hamper the method's reproducibility, as observed in an initial experiment setup that prioritizes short TEs with severely truncated acquisition for the benefit of signal‐to‐noise ratio (SNR). Nevertheless, CRLB have been confirmed to be well suited as design criteria, and within‐session repeatability approaches CRLB when residual water is removed in postprocessing by exploiting longer and less truncated data recordings. MESS MRS combined with 2D model fitting promises comparable accuracy, increased precision, or inversely shorter experimental times compared with traditional approaches. However, the optimal design must be investigated as a trade‐off between SNR, the truncation factor, and TE batch selections, all of which influence the robustness of estimations.

Funder

Horizon 2020 Framework Programme

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Publisher

Wiley

Subject

Spectroscopy,Radiology, Nuclear Medicine and imaging,Molecular Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3