Artifact removal for unpaired thorax CBCT images using a feature fusion residual network and contextual loss

Author:

Zhuang Wenqin1ORCID,Li Zheng1,Liu Haochen1,Ying Hu1,Yan Mo1

Affiliation:

1. College of Communications and Information Engineering Nanjing University of Posts and Telecommunications Nanjing China

Abstract

AbstractBackground and objectiveCone‐beam computed tomography (CBCT) has become a more and more active cutting‐edge topic in the international computed tomography (CT) research due to its advantages of fast scanning speed, high ray utilization rate and high precision. However, scatter artifacts affect the imaging performance of CBCT, which hinders its application seriously. Therefore, our study aimed to propose a novel algorithm for scatter artifacts suppression in thorax CBCT based on a feature fusion residual network (FFRN), where the contextual loss was introduced to adapt the unpaired datasets better.MethodsIn the method we proposed, a FFRN with contextual loss was used to reduce CBCT artifacts in the region of chest. Unlike L1 or L2 loss, the contextual loss function makes input images which are not aligned strictly in space available, so we performed it on our unpaired datasets. The algorithm aims to reduce artifacts via studying the mapping between CBCT and CT images, where the CBCT images were set as the beginning while planning CT images as the end.ResultsThe proposed method effectively removes artifacts in thorax CBCT, including shadow artifacts and cup artifacts which can be collectively referred to as uneven grayscale artifacts, in the CBCT image, and perform well in preserving details and maintaining the original shape. In addition, the average PSNR number of our proposed method achieved 27.7, which was higher than the methods this paper referred which indicated the significance of our method.ConclusionsWhat is revealed by the results is that our method provides a highly effective, rapid, and robust solution for the removal of scatter artifacts in thorax CBCT images. Moreover, as is shown in Table 1, our method has demonstrated better artifact reduction capability than other methods.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Reference31 articles.

1. Visual enhancement of Cone‐beam CT by use of CycleGAN

2. Scattering estimation for cone‐beam CT using local measurement based on compressed sensing;Yang F;IEEE Trans TNS,2018

3. Scatter correction method for cone‐beam CT based on interlacing‐slit scan;Huang KD;Chin Phys,2014

4. ZhangH ShiY HuangK An improved scatter correction method for cone beam computed tomography.IEEE ICSPCC.2011;1‐5.

5. Scatter correction algorithm for digitally acquired radiographs: Theory and results

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3