Dosimetric accuracy of the Convolution algorithm for Leksell Gamma Plan radiosurgery treatment planning: Evaluation in the presence of clinically relevant inhomogeneities

Author:

Pantelis Evaggelos1,Logothetis Andreas1,Zoros Emmanouil1,Pappas Eleftherios P.1,Papagiannis Panagiotis1,Paddick Ian2,Nordström Håkan3,Kollias George4,Karaiskos Pantelis1

Affiliation:

1. Medical Physics Laboratory Medical School National and Kapodistrian University of Athens Athens Greece

2. Medical Genesis Care Centre for Radiotherapy Cromwell Hospital London UK

3. Elekta Instrument AB Stockholm Sweden

4. Departments of Medical Physics and Gamma Knife Hygeia Hospital Athens Greece

Abstract

AbstractPurposeThe Leksell Gamma Plan Convolution algorithm (LGP‐Convolution) has not been widely adopted. This mainly stems from the higher calculated beam‐on times relative to the standard ray tracing‐based LGP‐TMR10 dose calculation algorithm. This study aims to evaluate the accuracy of the LGP‐Convolution in scenarios where the treated lesions are in the vicinity of or encompassed by bone and/or air inhomogeneities.MethodsThe solid water dosimetry phantom provided by the vendor was modified to include bone and air inhomogeneities. Two treatment planning scenarios were investigated involving a single shot and multiple shots, respectively. Treatment planning and dose prescription were performed using the LGP‐Convolution algorithm. Triple channel film dosimetry was performed using GafChromic EBT3 films calibrated in terms of absorbed dose to water in a 60Co beam. Monte Carlo (MC) simulation dosimetry was also performed in the inhomogeneous experimental geometry using the EGSnrc MC platform and a previously validated sector‐based phase‐space source model. MC simulations were also employed to determine correction factors required for converting EBT3 measurements at points within the bone and air inhomogeneities from dose‐to‐water values to the corresponding dose to medium values.Results and ConclusionsEBT3 dose to medium correction factors ranged with field size (4, 8, or 16 mm) within 0.941–0.946 for bone and 0.745–0.749 for air inhomogeneities. An excellent agreement was found between the LGP‐Convolution calculations with corresponding EBT3 and MC dose to medium results at all measurement points, except those located inside the air inhomogeneity. The latter is of no clinical importance and excluding them yielded gamma index passing rates of nearly 100% for 3% local dose difference and 1 mm distance‐to‐agreement criteria. The excellent agreement observed between LGP‐Convolution calculations and film as well as MC results of dose to medium indicates that the latter is the quantity reported by the LGP‐Convolution.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Reference36 articles.

1. Gamma Knife Radiosurgery

2. Recommendations on the practice of calibration, dosimetry, and quality assurance for gamma stereotactic radiosurgery: Report of AAPM Task Group 178

3. ElektaAB.A New TMR Dose Algorithm in Leksell GammaPlan.2011.

4. ElektaAB.The Convolution Algorithm in Leksell GammaPlan ® 10.2011.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3