The effect of common dental fixtures on treatment planning and delivery for head and neck intensity modulated proton therapy

Author:

Hu Yue‐Houng1,Seum Wan Chan Tseung Hok2,Hunzeker Ashley2,Muller Olivia3,Foote Robert L.2,Mundy Daniel W.2

Affiliation:

1. Department of Radiation Oncology Division of Medical Physics and Biophysics Brigham and Women's Hospital Dana‐Farber Cancer Institute, and Harvard Medical School Boston Massachusetts USA

2. Department of Radiation Oncology Division of Medical Physics Mayo Clinic Rochester Minnesota USA

3. Department of Advanced Prosthodontics Mayo Clinic Rochester Minnesota USA

Abstract

AbstractPurposeProton treatment plan perturbation by common dental fixtures such as amalgams (Am) and porcelain‐fused‐to‐metal (PFM) crowns has, to date, been uncharacterized. Previous studies have been conducted to determine the physical effect of these materials within the beam path for single spots, but their effects on complex treatment plans and clinical anatomy have not yet been quantified. The present manuscript aims to study the effect of Am and PFM fixtures on proton treatment planning in a clinical setting.MethodsAn anthropomorphic phantom with removable tongue, maxilla, and mandible modules was simulated on a clinical computed tomography (CT) scanner. Spare maxilla modules were modified to include either a 1.5 mm depth central groove occlusal amalgam (Am) or a porcelain‐fused‐to‐metal (PFM) crown, implanted on the first right molar. Modified tongue modules were 3D printed to accommodate several axial or sagittal oriented pieces of EBT‐3 film. Clinically representative spot‐scanning proton plans were generated in Eclipse v.15.6 using the proton convolution superposition (PCS) algorithm v.15.6.06 using a multi‐field optimization (MFO) technique with the goal of delivering a uniform 54 Gy dose to a clinical target volume (CTV) typical of a base‐of‐tongue (BoT) treatment. A typical geometric beam arrangement of two anterior oblique (AO) beams and a posterior beam was employed. Plans optimized without any material overrides were delivered to the phantom A) without implants; B) with Am fixture; or C) with PFM crown. Plans were also reoptimized and delivered with inclusion of material overrides to equate relative stopping power of the fixture with that of a previously measured result.ResultsPlans exhibit slightly greater dose weight towards AO beams. The optimizer accounted for inclusion of fixture overrides by increasing beam weights to the beam closest to the implant. Film measurements exhibited cold spots directly within the beam path through the fixture in plans with and without overridden materials. Cold spots were somewhat mitigated in plans including overridden materials in the structure set but were not entirely eliminated. Cold spots associated with Am and PFM fixtures were quantified at 17% and 14% for plans without overrides, respectively, and 11% and 9% with using Monte Carlo simulation. Compared with film measurements and Monte Carlo simulation, the treatment planning system underestimates the dose shadowing effect in plans including material overrides.ConclusionsDental fixtures create a dose shadowing effect directly in line with the beam path through the material. This cold spot is partially mitigated by overriding the material to measured relative stopping powers. Due to uncertainties in modeling perturbation through the fixture, the magnitude of the cold spot is underestimated using the institutional TPS when compared to measurement and MC simulation.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3