Reproducibility and stability of spirometer‐guided deep inspiration breath‐hold in left‐breast treatments using an optical surface monitoring system

Author:

Cilla Savino1,Romano Carmela1,Craus Maurizio1,Viola Pietro1,Macchia Gabriella2,Boccardi Mariangela2,De Vivo Livia P.2,Buwenge Milly34ORCID,Morganti Alessio G.34,Deodato Francesco2

Affiliation:

1. Medical Physics Unit Gemelli Molise Hospital Università Cattolica del Sacro Cuore Campobasso Italy

2. Radiation Oncology Unit Gemelli Molise Hospital Università Cattolica del Sacro Cuore Campobasso Italy

3. Radiation Oncology Department IRCCS Azienda Ospedaliero‐Universitaria di Bologna Bologna Italy

4. DIMES, Alma Mater Studiorum Bologna University Bologna Italy

Abstract

AbstractThe aim of this study was to evaluate the reproducibility and stability of left breast positioning during spirometer‐guided deep‐inspiration breath‐hold (DIBH) radiotherapy using an optical surface imaging system (AlignRT). The AlignRT optical tracking system was used to monitor five left‐sided breast cancer patients treated using the Active Breathing Coordinator spirometer with DIBH technique. Treatment plans were created using an automated hybrid‐VMAT technique on DIBH CTs. A prescribed dose of 60 Gy to the tumor bed and 50 Gy to the breast in 25 fractions was planned. During each treatment session, the antero‐posterior (VRT), superior‐inferior (LNG), and lateral (LAT) motion of patients was continuously recorded by AlignRT. The intra‐breath‐hold stability and the intra‐ and inter‐fraction reproducibility were analyzed for all breath‐holds and treatment fractions. The dosimetric impact of the residual motion during DIBH was evaluated from the isocenter shifts amplitudes obtained from the 50%, 90%, and 100% cumulative distribution functions of intra‐fractional reproducibility. The positional variations of 590 breath‐holds as measured by AlignRT were evaluated. The mean intra‐breath‐hold stability during DIBH was 1.0 ± 0.4 mm, 2.1 ± 1.9 mm, and 0.7 ± 0.5 mm in the VRT, LNG, and LAT directions, with a maximal value of 8.8 mm in LNG direction. Similarly, the mean intra‐breath‐hold reproducibility was 1.4 ± 0.8 mm, 1.7 ± 1.0 mm, and 0.8 ± 0.5 mm in the VRT, LNG, and LAT directions, with a maximal value of 4.1 mm in LNG direction. Inter‐fractional reproducibility showed better reliability, with difference in breathing levels in all fractions of 0.3 mm on average. Based on tolerance limits corresponding to the 90% cumulative distribution level, gating window widths of 1 mm, 2 mm, and 5 mm in the LAT, VRT, and LNG directions were considered an appropriate choice. In conclusion, despite the use of a dedicated spirometer at constant tidal volume, a non‐negligible variability of the breast surface position has been reported during breath‐holds. The real‐time monitoring of breast surface using surface‐guided optical technology is strongly recommended.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3