Stability of dosiomic features against variations in dose calculation: An analysis based on a cohort of prostate external beam radiotherapy patients

Author:

Sun Lingyue12,Smith Wendy123,Kirkby Charles134

Affiliation:

1. Department of Physics and Astronomy University of Calgary Calgary Alberta Canada

2. Department of Medical Physics Tom Baker Cancer Centre Calgary Alberta Canada

3. Department of Oncology University of Calgary Calgary Alberta Canada

4. Department of Medical Physics Jack Ady Cancer Centre Lethbridge Alberta Canada

Abstract

AbstractIntroductionInterest in using higher order features of the planned 3D dose distributions (i.e., dosiomics) to predict radiotherapy outcomes is growing. This is driving many retrospective studies where historical data are mined to train machine learning models; however, recent decades have seen considerable advances in dose calculation that could have a direct impact on the dosiomic features such studies seek to extract. Is it necessary to recalculate planned dose distributions using a common algorithm if retrospective datasets from different institutions are included? Does a change in dose calculation grid size part way through a retrospective cohort, introduce bias in the extracted dosiomic features? The purpose of this study is to assess the stability of dosiomic features against variations in three factors: the dose calculation algorithm type, version, and dose grid size.MethodsDose distributions for 27 prostate patients who received EBRT were recalculated in the Eclipse Treatment Planning System (Varian Medical Systems, Palo Alto, California, USA) using two algorithms (AAA and Acuros XB), two versions (version 13.6 and 15.6), and three dose grids (2, 2.5 s, and 3 mm) – 12 dose distributions for each patient. Ninety‐three dosiomic features were extracted from each dose distribution and each of the following regions‐of‐interest: high dose PTV (PTV_High), 1 cm rind around PTV_High (PTV_Ring), low dose PTV (PTV_Low), rectum, and bladder using PyRadiomics. The coefficient of variation (CV) was calculated for each dosiomic feature. Hierarchical clustering was used to group features with high and low variability. Three‐way repeated measures ANOVA was performed to investigate the effect of the three different factors on dosiomic features that were classified with high variation. Additionally, CVs were calculated for cumulative dose volume histograms (DVHs) to test their ability to detect the variations in dose distributions.ResultsFor PTV_Ring, PTV_Low, and rectum, all the dosiomic features had low CV (average CV 0.26) across the varying dose calculation conditions. For PTV_High, six dosiomic features showed CV > 0.26, and dose calculation algorithm type and grid size were the major sources of within‐patient variation. For bladder, one dosiomic feature had average CV > 0.26, but none of the three dose calculation‐related factors led to a statistically significant variation. The CVs for all the DVHs were very small (CV < 0.05).ConclusionFor all the regions‐of‐interest examined in this study, the majority of the dosiomic features were stable against variations in dose calculation; however, some of the dosiomic features for PTV_High and bladder had significant variations due to differences in dose calculation details. DVHs were detecting less variation than dosiomic features.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3