Individualized breathing trace quality assurance for lung radiotherapy patients undergoing 4DCT simulation

Author:

Rijken James1,Hu Yunfei2ORCID,Hiscoke Kelvin3

Affiliation:

1. Icon Cancer Centre Windsor Gardens South Australia Australia

2. Icon Cancer Centre Gosford New South Wales Australia

3. Icon Cancer Centre Wellington New Zealand

Abstract

Abstract4DCT simulation is a popular solution for radiotherapy simulation of lung cancer patients as it allows the clinician to gain an appreciation for target motion during the patient breathing cycle. Resultant binning of images and production of the 4DCT dataset relies heavily on the recorded breathing trace; but quality assurance is not routinely performed on these and there lacks any substantial recommendations thereof.An application was created for Windows in C# that was able to analyze the VXP breathing trace files from Varian RPM/RGSC and quantify various metrics associated with the patient breathing cycle. This data was then used to consider errors in voluming of targets for several example cases in order to justify recommendations on quality assurance.For 281 real patient breathing traces from 4DCT simulation of lung targets, notable differences were found between RGSC and application calculations of phase data. For any new patient without individualized QA, the average marked phase calculation (which is used for 4DCT reconstruction) is only accurate to within 19% of the actual phases. The error in BPM within the scan due to breathing rate variation is 37%. The uncertainty in amplitude due to breathing variation is 34% in the mean. Phase uncertainty leads to misbinning which we have shown can lead to missing 66% of the target for gated treatment. Variation in inhalation/exhalation level leads to voluming errors which, without individualized QA, can be assumed to be 11% (PTV is smaller than actual).Without individualized quality assurance of patient breathing traces, large uncertainties have to be assumed for metrics of both phase and amplitude, leading to clinically significant uncertainties in treatment. It is recommended to perform individualized quality assurance as this provides the clinician with an accurate quantification of uncertainty for their patient.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3