Preliminary dosimetric comparison between fixed and rotating source stereotactic radiosurgery systems

Author:

Draeger Emily1,Chen Zhe (Jay)1,Hansen James E.1,Chiang Veronica12,Tien Christopher J.1

Affiliation:

1. Department of Therapeutic Radiology Yale University School of Medicine New Haven Connecticut USA

2. Department of Neurosurgery Yale University School of Medicine New Haven Connecticut USA

Abstract

AbstractPurposeThe Akesis Galaxy RTi (AK) is a novel rotational 60Co‐based cranial stereotactic radiosurgery (SRS) system. While similar systems have been compared against the fixed‐source Leksell Gamma Knife (GK) system using stylized phantoms, dosimetric plan quality with realistic anatomy has yet to be characterized for this or any other rotating system versus GK. This study aims to benchmark AK dosimetric performance against GK by retrospectively replanning previously‐treated GK patients at our institution.MethodsThirteen patients, previously treated on a GK Icon, were re‐planned on the AK treatment planning system using the same prescription doses and isodoses as the original GK plans. The cohort includes patients treated for brain metastases, schwannomas, pituitary adenomas, trigeminal neuralgias, and arteriovenous malformations. Plans are evaluated with target coverage metrics (Dmin, Dmean, D95%, V150%) and dose conformality indices: Radiation Therapy Oncology Group conformity index (CI), selectivity, Paddick CI (PCI), gradient index (GI).ResultsAK plans use fewer shots and larger collimation compared to GK plans, resulting in statistically significant reductions in treatment time (p = 0.047) by as much as 88.4 minutes while maintaining comparable target V100%. For most metastatic cases, GK produces higher Dmin (16.0–25.9 vs. 12.5–24.3 Gy, p = 0.008) while AK produces higher V150% (0.03–14.92 vs. 0.02–11.59 cc, p = 0.028). For non‐metastatic cases, GK provides superior CI (p = 0.025) and GI (p = 0.044). No statistically significant differences were found in the remaining metrics.ConclusionThis cohort demonstrates that the AK system is able to achieve largely comparable dosimetric results to GK, typically with shorter treatment times. Further investigation with a larger cohort is underway.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3