Intensity modulated proton arc therapy via geometry‐based energy selection for ependymoma

Author:

Cao Wenhua1ORCID,Li Yupeng1,Zhang Xiaodong1,Poenisch Falk1,Yepes Pablo12,Sahoo Narayan1ORCID,Grosshans David3,McGovern Susan3,Gunn G. Brandon3,Frank Steven J.3,Zhu Xiaorong R.1

Affiliation:

1. Department of Radiation Physics The University of Texas MD Anderson Cancer Center Houston Texas USA

2. Department of Physics and Astronomy Rice University Houston Texas USA

3. Department of Radiation Oncology The University of Texas MD Anderson Cancer Center Houston Texas USA

Abstract

AbstractPurposeWe developed and tested a novel method of creating intensity modulated proton arc therapy (IMPAT) plans that uses computing resources similar to those for regular intensity‐modulated proton therapy (IMPT) plans and may offer a dosimetric benefit for patients with ependymoma or similar tumor geometries.MethodsOur IMPAT planning method consists of a geometry‐based energy selection step with major scanning spot contributions as inputs computed using ray‐tracing and single‐Gaussian approximation of lateral spot profiles. Based on the geometric relation of scanning spots and dose voxels, our energy selection module selects a minimum set of energy layers at each gantry angle such that each target voxel is covered by sufficient scanning spots as specified by the planner, with dose contributions above the specified threshold. Finally, IMPAT plans are generated by robustly optimizing scanning spots of the selected energy layers using a commercial proton treatment planning system (TPS). The IMPAT plan quality was assessed for four ependymoma patients. Reference three‐field IMPT plans were created with similar planning objective functions and compared with the IMPAT plans.ResultsIn all plans, the prescribed dose covered 95% of the clinical target volume (CTV) while maintaining similar maximum doses for the brainstem. While IMPAT and IMPT achieved comparable plan robustness, the IMPAT plans achieved better homogeneity and conformity than the IMPT plans. The IMPAT plans also exhibited higher relative biological effectiveness (RBE) enhancement than did the corresponding reference IMPT plans for the CTV in all four patients and brainstem in three of them.ConclusionsThe proposed method demonstrated potential as an efficient technique for IMPAT planning and may offer a dosimetric benefit for patients with ependymoma or tumors in close proximity to critical organs. IMPAT plans created using this method had elevated RBE enhancement associated with increased linear energy transfer (LET) in both targets and abutting critical organs.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3