Comparison of MR‐soft tissue based versus biliary stent based alignment for image guidance in pancreatic SBRT

Author:

Han Zhaohui1,Sudhyadhom Atchar1,Hsu Shu‐Hui1,Hu Yue‐Houng1,Mak Raymond H.1,Huynh Mai Anh1,van Dams Ritchell R.1,Tanguturi Shyam1,Venkatachalam Veena1,Mancias Joseph D.1,Mamon Harvey J.1,Martin Neil E.1,Lam Miranda B.1,Leeman Jonathan E.1

Affiliation:

1. Department of Radiation Oncology Brigham and Women's Hospital and Dana‐Farber Cancer Institute Harvard Medical School Boston Massachusetts USA

Abstract

AbstractPurposeThe role of biliary stents in image‐guided localization for pancreatic cancer has been inconclusive. To date, stent accuracy has been largely evaluated against implanted fiducials on cone beam computed tomography. We aim to use magnetic resonance (MR) soft tissue as a direct reference to examine the geometric and dosimetric impacts of stent‐based localization on the newly available MR linear accelerator.MethodsThirty pancreatic cancer patients (132 fractions) treated on our MR linear accelerator were identified to have a biliary stent. In our standard adaptive workflow, patients were set up to the target using soft tissue for image registration and structures were re‐contoured on daily MR images. The original plan was then projected on treatment anatomy and dose predicted, followed by plan re‐optimization and treatment delivery. These online predicted plans were soft tissue‐based and served as reference plans. Retrospective image registration to the stent was performed offline to simulate stent‐based localization and the magnitude of shifts was taken as the geometric accuracy of stent localization. New predicted plans were generated based on stent‐alignment for dosimetric comparison.ResultsShifts were within 3 mm for 90% of the cases (mean = 1.5 mm); however, larger shifts up to 7.2 mm were observed. Average PTV coverage dropped by 1.1% with a maximum drop of 26.8%. The mean increase in V35Gy was 0.15, 0.05, 0.02, and 0.02 cc for duodenum, stomach, small bowel and large bowel, respectively. Stent alignment was significantly worse for all metrics except for small bowel (p = 0.07).ConclusionsOverall discrepancy between stent‐ and soft tissue‐alignment was modest; however, large discrepancies were observed for select cases. While PTV coverage loss may be compensated for by using a larger margin, the increase in dose to gastrointestinal organs at risk may limit the role of biliary stents in image‐guided localization.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3