IMRT QA result prediction via MLC transmission decomposition

Author:

Stasko John T.1ORCID,Ferris William S.1ORCID,Adam David P.1ORCID,Culberson Wesley S.1ORCID,Frigo Sean P.12ORCID

Affiliation:

1. Department of Medical Physics School of Medicine and Public Health University of Wisconsin‐Madison Madison Wisconsin USA

2. Department of Human Oncology School of Medicine and Public Health University of Wisconsin‐Madison Madison Wisconsin USA

Abstract

AbstractBackgroundQuality assurance measurement of IMRT/VMAT treatment plans is resource intensive, and other more efficient methods to achieve the same confidence are desirable.PurposeWe aimed to analyze treatment plans in the context of the treatment planning systems that created them, in order to predict which ones will fail a standard quality assurance measurement. To do so, we sought to create a tool external to the treatment planning system that could analyze a set of MLC positions and provide information that could be used to calculate various evaluation metrics.MethodsThe tool was created in Python to read in DICOM plan files and determine the beam fluence fraction incident on each of seven different zones, each classified based on the RayStation MLC model. The fractions, termed grid point fractions, were validated by analyzing simple test plans. The average grid point fractions, over all control points for 46 plans were then computed. These values were then compared with gamma analysis pass percentages and median dose differences to determine if any significant correlations existed.ResultsSignificant correlation was found between the grid point fraction metrics and median dose differences, but not with gamma analysis pass percentages. Correlations were positive or negative, suggesting differing model parameter value sensitivities, as well as potential insight into the treatment planning system dose model.ConclusionsBy decomposing MLC control points into different transmission zones, it is possible to create a metric that predicts whether the analyzed plan will pass a quality assurance measurement from a dose calculation accuracy standpoint. The tool and metrics developed in this work have potential applications in comparing clinical beam models or identifying their weak points. Implementing the tool within a treatment planning system would also provide more potential plan optimization parameters.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3