Dosimetric characterization of a novel commercial plastic scintillation detector with an MR‐Linac

Author:

Ferrer Carlos1,Huertas Concepción1,García David1,Sáez Moisés1

Affiliation:

1. Medical Physics and Radiation Protection Department La Paz University Hospital Madrid Spain

Abstract

AbstractBackgroundPlastic scintillators have been used as radiation detectors for the past few years, as they are water‐equivalent and independent of the dose, dose rate, and angle of incidence. In addition, they are also independent of the presence of a magnetic field and could be used for in vivo dosimetry in an MR‐Linac. With the advent of a new commercial scintillation detector, Blue Physics Model 10, its characterization has been performed on an MR‐Linac with a view to future applications.PurposeTo perform the dosimetric characterization and study potential applications of a novel commercial plastic scintillation detector in a MR‐Linac.MethodsScintillation detector description, calibration procedure, short‐term repeatability, dose‐response linearity, dose‐rate dependence, angular dependence, and temperature dependence have been studied. Percent‐depth‐dose (PDD) and beam profiles were measured for small fields and a standard field, as well as output factors, for comparison with other PTW detectors: a diamond diode and PinPoint and Semiflex 3D ionization chambers. The suitability of the plastic scintillator for in vivo dosimetry in a magnetic field has also been studied measuring the dose to a point in an anthropomorphic phantom while acquiring MR imaging. This measured dose was compared with that calculated with Monaco planning system and with that measured with a PTW Semiflex 3D chamber, the latter without acquiring MR images.ResultsShort‐term repeatability presented negligible variations (<0.4%) for 100 and 20 MU. Similar results were obtained for dose‐response linearity and dose‐rate dependence. A small angular dependence was determined, while the scintillator resulted practically independent of the temperature. PDDs showed excellent agreement except in the build‐up region, and calculated penumbras with the profiles given by the scintillator were between the ones obtained with the diamond detector and the PinPoint ionization chamber. Measured OF with the scintillator were the highest between all detectors, 1.26% higher than the value obtained with the microdiamond for the smallest field measured, 0.5 × 0.5 cm2. Finally, the total dose to a point measured with the scintillator was 0.51% higher compared to that calculated by the planning system.ConclusionThe Blue Physics model 10 scintillation system showed excellent dosimetric characteristics. Its response independent of the temperature and the presence of a magnetic field make it suitable for in vivo dosimetry in an MR‐Linac while acquiring MR images, which could solve the impossibility of performing a dosimetric QA for each adapted plan. Furthermore, its temporal resolution allows independent radiation pulses to be measured and visualized, which could be used in future applications.

Publisher

Wiley

Subject

General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3