Dissociation Phenomenon of Erythrocyte Agglutination and Its Application to Assay of Functional Activity of the Complement System in Clinical Laboratory

Author:

Ding Xuewei1,Liu Lina2,Yang Guang1,Liu Hui1ORCID

Affiliation:

1. College of Medical Laboratory Dalian Medical University Dalian China

2. Second Afliated Hospital of Dalian Medical University Dalian China

Abstract

ABSTRACTObjectiveThe objective of the study was to validate the dissociation phenomenon of erythrocyte agglutination which is based on erythrocyte fragments and to apply it in the functional activity assay of the complement system.MethodsThe dissociation–agglutination effect of erythrocyte fragments was validated by detecting the number of free erythrocytes after the action of erythrocyte fragments on agglutinated erythrocytes. The number of free erythrocytes produced after hemolysis of agglutinated erythrocytes caused by complements and complement activators(CAs) was detected by auto hematology analyzer and the results were indicated by mean hemoglobin concentration of erythrocytes (MCHC). We optimized the test conditions and validated the inter‐batch stability, explored the resolution of the assay method, and assayed for the total complement activity (AC) and the CAs activated complement activity (ACA) in serum from patients and healthy individual groups.ResultsErythrocyte fragments have a dissociative effect on agglutinated erythrocytes. The auto hematology analyzer was able to detect AC and ACA, where AC showed an inverse correlation with MCHC, and ACA demonstrated a positive correlation with MCHC. The inter‐batch CV of AC, ACA, and ACA/AC was found to be 5%, 9%, and 11.7%, respectively, with good stability. The study found that serum samples from acute phase reaction patients showed significant differences in ACA compared with healthy individuals, with a p value of 0.018; serum samples from patients with nephrotic syndrome showed significant differences in AC, ACA, and ACA/AC compared with healthy individuals, with p values of 0.014, 0.002, and 0.041, respectively.ConclusionErythrocyte fragments have dissociation–agglutination effect. The complement system immunological functional detection method, based on this effect, has potential clinical application value due to its sensitivity and accuracy.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3