Validation of rectal sparing throughout the course of proton therapy treatment in prostate cancer patients treated with SpaceOAR®

Author:

Hedrick Samantha G.1,Fagundes Marcio1,Case Sara1,Renegar Jackson1,Blakey Marc1,Artz Mark1,Chen Hao1,Robison Ben1,Schreuder Niek1

Affiliation:

1. Provision Center for Proton Therapy Knoxville TN USA

Abstract

AbstractThe purpose of this study was to investigate the consistency of rectal sparing using multiple periodic quality assurance computerized tomography imaging scans (QACT) obtained during the course of proton therapy for patients with prostate cancer treated with a hydrogel spacer. Forty‐one low‐ and intermediate‐risk prostate cancer patients treated with image‐guided proton therapy with rectal spacer hydrogel were analyzed. To assess the reproducibility of rectal sparing with the hydrogel spacer, three to four QACTs were performed for each patient on day 1 and during weeks 1, 3, and 5 of treatment. The treatment plan was calculated on the QACT and the rectum V90%, V75%, V65%, V50%, and V40% were evaluated. For the retrospective analysis, we evaluated each QACT and compared it to the corresponding treatment planning CT (TPCT), to determine the average change in rectum DVH points. We were also interested in how many patients exceeded an upper rectum V90% threshold on a QACT. Finally, we were interested in a correlation between rectum volume and V90%. On each QACT, if the rectum V90% exceeded the upper threshold of 6%, the attending physician was notified and the patient was typically prescribed additional stool softeners or laxatives and reminded of dietary compliance. In all cases of the rectum V90% exceeding the threshold, the patient had increased gas and/or stool, compared to the TPCT. On average, the rectum V90% calculated on the QACT was 0.81% higher than that calculated on the TPCT. The average increase in V75%, V65%, V50%, and V40% on the QACT was 1.38%, 1.59%, 1.87%, and 2.17%, respectively. The rectum V90% was within ± 1% of the treatment planning dose in 71.2% of the QACTs, and within ± 5% in 93.2% of the QACTs. The 6% threshold for rectum V90% was exceeded in 7 out of 144 QACTs (4.8%), identified in 5 of the 41 patients. We evaluated the average rectum V90% across all QACTs for each of these patients, and it was found that the rectum V90% never exceeded 6%. 53% of the QACTs had a rectum volume within 5 cm3 of the TPCT volume, 68% were within 10 cm3. We found that patients who exceeded the threshold on one or more QACTs had a lower TPCT rectal volume than the overall average. By extrapolating patient anatomy from three to four QACT scans, we have shown that the use of hydrogel in conjunction with our patient diet program and use of stool softeners is effective in achieving consistent rectal sparing in patients undergoing proton therapy.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3