Development and validation of a noise insertion algorithm for photon‐counting‐detector CT

Author:

Winfree Timothy1,McCollough Cynthia1,Yu Lifeng1

Affiliation:

1. Department of Radiology Mayo Clinic Rochester Minnesota USA

Abstract

AbstractBackgroundInserting noise into existing patient projection data to simulate lower‐radiation‐dose exams has been frequently used in traditional energy‐integrating‐detector (EID)‐CT to optimize radiation dose in clinical protocols and to generate paired images for training deep‐learning‐based reconstruction and noise reduction methods. Recent introduction of photon counting detector CT (PCD‐CT) also requires such a method to accomplish these tasks. However, clinical PCD‐CT scanners often restrict the users access to the raw count data, exporting only the preprocessed, log‐normalized sinogram. Therefore, it remains a challenge to employ projection domain noise insertion algorithms on PCD‐CT.PurposeTo develop and validate a projection domain noise insertion algorithm for PCD‐CT that does not require access to the raw count data.Materials and MethodsA projection‐domain noise model developed originally for EID‐CT was adapted for PCD‐CT. This model requires, as input, a map of the incident number of photons at each detector pixel when no object is in the beam. To obtain the map of incident number of photons, air scans were acquired on a PCD‐CT scanner, then the noise equivalent photon number (NEPN) was calculated from the variance in the log normalized projection data of each scan. Additional air scans were acquired at various mA settings to investigate the impact of pulse pileup on the linearity of NEPN measurement. To validate the noise insertion algorithm, Noise Power Spectra (NPS) were generated from a 30 cm water tank scan and used to compare the noise texture and noise level of measured and simulated half dose and quarter dose images. An anthropomorphic thorax phantom was scanned with automatic exposure control, and noise levels at different slice locations were compared between simulated and measured half dose and quarter dose images. Spectral correlation between energy thresholds T1 and T2, and energy bins, B1 and B2, was compared between simulated and measured data across a wide range of tube current. Additionally, noise insertion was performed on a clinical patient case for qualitative assessment.ResultsThe NPS generated from simulated low dose water tank images showed similar shape and amplitude to that generated from the measured low dose images, differing by a maximum of 5.0% for half dose (HD) T1 images, 6.3% for HD T2 images, 4.1% for quarter dose (QD) T1 images, and 6.1% for QD T2 images. Noise versus slice measurements of the lung phantom showed comparable results between measured and simulated low dose images, with root mean square percent errors of 5.9%, 5.4%, 5.0%, and 4.6% for QD T1, HD T1, QD T2, and HD T2, respectively. NEPN measurements in air were linear up until 112 mA, after which pulse pileup effects significantly distort the air scan NEPN profile. Spectral correlation between T1 and T2 in simulation agreed well with that in the measured data in typical dose ranges.ConclusionsA projection‐domain noise insertion algorithm was developed and validated for PCD‐CT to synthesize low‐dose images from existing scans. It can be used for optimizing scanning protocols and generating paired images for training deep‐learning‐based methods.

Funder

National Institutes of Health

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3