Automated data transfer for digital twin applications: Two case studies

Author:

Molin Hanna12ORCID,Wärff Christoffer13,Lindblom Erik12,Arnell Magnus13,Carlsson Bengt4,Mattsson Per4,Bäckman Jonas5,Jeppsson Ulf1

Affiliation:

1. Division of Industrial Electrical Engineering and Automation (IEA), Department of Biomedical Engineering Lund University Lund Sweden

2. IVL Swedish Environmental Research Institute Stockholm Sweden

3. RISE Research Institutes of Sweden AB Gothenburg Sweden

4. Division of Systems and Control, Department of Information Technology Uppsala University Uppsala Sweden

5. Gemit Solutions AB Stockholm Sweden

Abstract

AbstractDigital twins have been gaining an immense interest in various fields over the last decade. Bringing conventional process simulation models into (near) real time are thought to provide valuable insights for operators, decision makers, and stakeholders in many industries. The objective of this paper is to describe two methods for implementing digital twins at water resource recovery facilities and highlight and discuss their differences and preferable use situations, with focus on the automated data transfer from the real process. Case 1 uses a tailor‐made infrastructure for automated data transfer between the facility and the digital twin. Case 2 uses edge computing for rapid automated data transfer. The data transfer lag from process to digital twin is low compared to the simulation frequency in both systems. The presented digital twin objectives can be achieved using either of the presented methods. The method of Case 1 is better suited for automatic recalibration of model parameters, although workarounds exist for the method in Case 2. The method of Case 2 is well suited for objectives such as soft sensors due to its integration with the SCADA system and low latency. The objective of the digital twin, and the required latency of the system, should guide the choice of method.Practitioner Points Various methods can be used for automated data transfer between the physical system and a digital twin. Delays in the data transfer differ depending on implementation method. The digital twin objective determines the required simulation frequency. Implementation method should be chosen based on the required simulation frequency.

Funder

Stockholm Vatten och Avfall

IVL Svenska Miljöinstitutet

Svenskt Vatten

Svenska Forskningsrådet Formas

Siemens

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3