Effect of continuous local dexamethasone on tissue biomechanics and histology after inhalational burn in a preclinical model

Author:

Malka Ronit1ORCID,Gonzales Gabriela2,Detar Will1,Marinelli Lisa3ORCID,Lee Christine M.3,Isaac Alisa24,Miar Solaleh25,Cook Stacy1,Guda Teja24ORCID,Dion Gregory R.6ORCID

Affiliation:

1. Department of Biomedical Engineering and Chemical Engineering University of Texas at San Antonio San Antonio Texas USA

2. Department of Otolaryngology—Head and Neck Surgery Brooke Army Medical Center, JBSA Fort Sam Houston Houston Texas USA

3. Department of Pathology and Area Laboratory Services Brooke Army Medical Center, JBSA Fort Sam Houston Houston Texas USA

4. Department of Cell Systems and Anatomy University of Texas Health San Antonio San Antonio Texas USA

5. Department of Civil, Environmental, and Biomedical Engineering University of Hartford West Hartford Connecticut USA

6. Department of Otolaryngology—Head and Neck Surgery University of Cincinnati Cincinnati Ohio USA

Abstract

AbstractObjectiveInhalational burns frequently lead to dysphonia and airway stenosis. We hypothesize local dexamethasone delivery via a novel drug‐eluting electrospun polymer‐mesh endotracheal tube (ETT) reduces biomechanical and histologic changes in the vocal folds in inhalational burn.MethodsDexamethasone‐loaded polymer mesh was electrospun onto ETTs trimmed to transglottic endolaryngeal segments and secured in nine Yorkshire Crossbreed swine with directed 150°C inhalation burns. Uncoated ETTs were implanted in nine additional swine with identical burns. ETT segments were maintained for 3 and 7 days. Vocal fold (VF) structural stiffness was measured using automated‐indentation mapping and compared across groups and to four uninjured controls, and matched histologic assessment performed. Statistical analysis was conducted using two‐way ANOVA with Tukey's post hoc test and Wilcoxon rank‐sum test.ResultsVF stiffness after burn decreased with longer intubation, from 19.4 (7.6) mN/mm at 3 days to 11.3 (5.2) mN/mm at 7 days (p < .0001). Stiffness similarly decreased with local dexamethasone, from 25.9 (17.2) mN/mm at 3 days to 18.1 (13.0) mN/mm at 7 days (p < .0001). VF stiffness in the dexamethasone group was increased compared to tissues without local dexamethasone (p = .0002), and all groups with ETT placement had higher tissue stiffness at 3 days (p < .001). No significant change in histologic evidence of epithelial ulceration or fibrosis was noted, while an increased degree of inflammation was noted in the dexamethasone group (p = .04).ConclusionLocal dexamethasone delivery increases VF stiffness and degree of inflammation compared to uncoated ETTs in an acute laryngeal burn model, reflected in early biomechanical and histologic changes in an inhalational burn model.

Funder

U.S. Army Institute of Surgical Research

Publisher

Wiley

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3