Open label, interventional, single arm multicentric clinical study to analyze the potency of VELNEZ nasal pack, post‐nasal surgery

Author:

Bellad Shama1,Parusharam Nagula2,Dhyani Vineeta3ORCID,Bablani Pankaj4,Pandey Siddharth4

Affiliation:

1. Department of ENT Jawaharlal Nehru Medical College Belagavi Karnataka India

2. Department of ENT Mahatma Gandhi Memorial Hospital Warangal Telangana India

3. Department of Pharmacy Practice KLE University Belagavi Karnataka India

4. Datt Mediproducts Pvt. Ltd. New Delhi India

Abstract

AbstractBackgroundNasal packs are central to nasal surgeries. Primarily, these packs function by controlling bleeding, modulating pain and reducing adhesions postsurgery. However, the major setback of the currently used conventional nasal packs is the unbearable pain the patient undergoes upon removal of these packs. To overcome this shortcoming a variety of biodegradable packs have emerged. This study was aimed at evaluating the safety, efficacy and tolerability of VELNEZ nasal packs. VELNEZ, a patented Datt Mediproducts Pvt. Ltd. nasal pack, is one of its kind biodegradable composite that fragments within a few days of application.MethodsEighty patients were included in an open label, interventional, single arm clinical study using clinical endpoints to investigate the safety and efficacy of nasal pack VELNEZ. The patients were questioned using a visual analog scale from discharge day to 28th postoperative day (9 follow‐up visits) at regular intervals. The standardized questionnaires for hemorrhage control, relief from postoperative pain, moderate obstruction, and pain were used.ResultsA total of 76 patients were enrolled in the study and 74 patients completed the study. VELNEZ nasal pack played a significant role in controlling hemorrhage and reducing postoperative pain. The average hemorrhage control time was 7.49 ± 3.90 min with only 34.24% of population complaining of pain on the sixth day of surgery (follow‐up 4). Forteen days postsurgery only 10.95% of subject population complained of postoperative pain. This biodegradable composite has an average fragmentation time of 4.7 days in the nasal cavity. In addition, this study did not observe any postoperative adverse events or serious adverse events.ConclusionVELNEZ, a fragmentable nasal pack, is comfortable, safe, and effective against postsurgery bleeding and pain.

Publisher

Wiley

Subject

Otorhinolaryngology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3