Three‐dimensional super resolution ultrasound imaging with a multi‐frequency hemispherical phased array

Author:

Deng Lulu1,Lea‐Banks Harriet1,Jones Ryan M.1,O'Reilly Meaghan A.12,Hynynen Kullervo123

Affiliation:

1. Physical Sciences Platform Sunnybrook Research Institute Toronto Ontario Canada

2. Department of Medical Biophysics University of Toronto Toronto Ontario Canada

3. Institute of Biomedical Engineering University of Toronto Toronto Ontario Canada

Abstract

AbstractBackgroundHigh resolution imaging of the microvasculature plays an important role in both diagnostic and therapeutic applications in the brain. However, ultrasound pulse‐echo sonography imaging the brain vasculatures has been limited to narrow acoustic windows and low frequencies due to the distortion of the skull bone, which sacrifices axial resolution since it is pulse length dependent.PurposeTo overcome the detect limit, a large aperture 256‐module sparse hemispherical transmit/receive array was used to visualize the acoustic emissions of ultrasound‐vaporized lipid‐coated decafluorobutane nanodroplets flowing through tube phantoms and within rabbit cerebral vasculature in vivo via passive acoustic mapping and super resolution techniques.MethodsNanodroplets were vaporized with 55 kHz burst‐mode ultrasound (burst length = 145 μs, burst repetition frequency = 9–45 Hz, peak negative acoustic pressure = 0.10–0.22 MPa), which propagates through overlying tissues well without suffering from severe distortions. The resulting emissions were received at a higher frequency (612 or 1224 kHz subarray) to improve the resulting spatial resolution during passive beamforming. Normal resolution three‐dimensional images were formed using a delay, sum, and integrate beamforming algorithm, and super‐resolved images were extracted via Gaussian fitting of the estimated point‐spread‐function to the normal resolution data.ResultsWith super resolution techniques, the mean lateral (axial) full‐width‐at‐half‐maximum image intensity was 16 ± 3 (32 ± 6) μm, and 7 ± 1 (15 ± 2) μm corresponding to ∼1/67 of the normal resolution at 612 and 1224 kHz, respectively. The mean positional uncertainties were ∼1/350 (lateral) and ∼1/180 (axial) of the receive wavelength in water. In addition, a temporal correlation between nanodroplet vaporization and the transmit waveform shape was observed, which may provide the opportunity to enhance the signal‐to‐noise ratio in future studies.ConclusionsHere, we demonstrate the feasibility of vaporizing nanodroplets via low frequency ultrasound and simultaneously performing spatial mapping via passive beamforming at higher frequencies to improve the resulting spatial resolution of super resolution imaging techniques. This method may enable complete four‐dimensional vascular mapping in organs where a hemispherical array could be positioned to surround the target, such as the brain, breast, or testicles.

Funder

Canadian Institutes of Health Research

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3