Superparamagnetic iron oxide nanoparticle enhanced percutaneous microwave ablation: Ex‐vivo characterization using magnetic resonance thermometry

Author:

Bhagavatula Sharath K.1,Panikkanvalappil Sajanlal R.2,Tokuda Junichi1,Levesque Vincent1,Tatarova Zuzana1,Liu Guigen1,Markert John E.1,Jonas Oliver1

Affiliation:

1. Department of Radiology Brigham and Women's Hospital Harvard Medical School Boston Massachusetts USA

2. Department of Imaging Dana‐Farber Cancer Institute and Harvard Medical School Boston Massachusetts USA

Abstract

AbstractBackgroundPercutaneous microwave ablation (pMWA) is a minimally invasive procedure that uses a microwave antenna placed at the tip of a needle to induce lethal tissue heating. It can treat cancer and other diseases with lower morbidity than conventional surgery, but one major limitation is the lack of control over the heating region around the ablation needle. Superparamagnetic iron oxide nanoparticles have the potential to enhance and control pMWA heating due to their ability to absorb microwave energy and their ease of local delivery.PurposeThe purpose of this study is to experimentally quantify the capabilities of FDA‐approved superparamagnetic iron oxide Feraheme nanoparticles (FHNPs) to enhance and control pMWA heating. This study aims to determine the effectiveness of locally injected FHNPs in increasing the maximum temperature during pMWA and to investigate the ability of FHNPs to create a controlled ablation zone around the pMWA needle.MethodsPMWA was performed using a clinical ablation system at 915 MHz in ex‐vivo porcine liver tissues. Prior to ablation, 50 uL 5 mg/mL FHNP injections were made on one side of the pMWA needle via a 23‐gauge needle. Local temperatures at the FHNP injection site were directly compared to equidistant control sites without FHNP. First, temperatures were compared using directly inserted thermocouples. Next, temperatures were measured non‐invasively using magnetic resonance thermometry (MRT), which enabled comprehensive four‐dimensional (volumetric and temporal) assessment of heating effects relative to nanoparticle distribution, which was quantified using dual‐echo ultrashort echo time (UTE) subtraction MR imaging. Maximum heating within FHNP‐exposed tissues versus control tissues were compared at multiple pMWA energy delivery settings. The ability to generate a controlled asymmetric ablation zone using multiple FHNP injections was also tested. Finally, intra‐procedural MRT‐derived heat maps were correlated with gold standard gross pathology using Dice similarity analysis.ResultsMaximum temperatures at the FHNP injection site were significantly higher than control (without FHNP) sites when measured using direct thermocouples (93.1 ± 6.0°C vs. 57.2 ± 8.1°C, p = 0.002) and using non‐invasive MRT (115.6 ± 13.4°C vs. 49.0 ± 10.6°C, p = 0.02). Temperature difference between FHNP‐exposed and control sites correlated with total energy deposition: 66.6 ± 17.6°C, 58.1 ± 8.5°C, and 20.8 ± 9.2°C at high (17.5 ± 2.2 kJ), medium (13.6 ± 1.8 kJ), and low (8.8 ± 1.1 kJ) energies, respectively (all pairwise p < 0.05). Each FHNP injection resulted in a nanoparticle distribution within 0.9 ± 0.2 cm radially of the injection site and a local lethal heating zone confined to within 1.1 ± 0.4 cm radially of the injection epicenter. Multiple injections enabled a controllable, asymmetric ablation zone to be generated around the ablation needle, with maximal ablation radius on the FHNP injection side of 1.6 ± 0.2 cm compared to 0.7 ± 0.2 cm on the non‐FHNP side (p = 0.02). MRT intra‐procedural predicted ablation zone correlated strongly with post procedure gold‐standard gross pathology assessment (Dice similarity 0.9).ConclusionsLocally injected FHNPs significantly enhanced pMWA heating in liver tissues, and were able to control the ablation zone shape around a pMWA needle. MRI and MRT allowed volumetric real‐time visualization of both FHNP distribution and FHNP‐enhanced pMWA heating that was useful for intra‐procedural monitoring. This work strongly supports further development of a FHNP‐enhanced pMWA paradigm; as all individual components of this approach are approved for patient use, there is low barrier for clinical translation.

Funder

National Institutes of Health

Radiological Society of North America

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3