Correcting CT misregistration in data‐driven gated (DDG) PET with PET self‐gating and deformable image registration

Author:

Sun Peng1,Thomas M. Allan2,Luo Dershan3,Pan Tinsu1

Affiliation:

1. Department of Imaging Physics UT MD Anderson Cancer Center Houston Texas USA

2. Mallinckrodt Institute of Radiology Washington University in St. Louis St. Louis Missouri USA

3. Department of Radiation Physics UT MD Anderson Cancer Center Houston Texas USA

Abstract

AbstractBackgroundMisregistration between CT and PET data can result in mis‐localization and inaccurate quantification of functional uptake in whole body PET/CT imaging. This problem is exacerbated when an abnormal inspiration occurs during the free‐breathing helical CT (FB CT) used for attenuation correction of PET data. In data‐driven gated (DDG) PET, the data selected for reconstruction is typically derived from the end‐expiration (EE) phase of the breathing cycle, making this potential issue worse.PurposeThe objective of this study is to develop a deformable image registration (DIR)‐based respiratory motion model to improve the registration and quantification between misregistered FB CT and PET.MethodsTwenty‐two whole‐body 18F‐FDG PET/CT scans encompassing 48 lesions in misregistered regions were analyzed in this study. End‐inspiration (EI) and EE PET data were derived from −10% to 15% and 30% to 80% of the breathing cycle, respectively. DIR was used to estimate a motion model from the EE to EI phase of the PET data. The model was then used to generate PET images at any phase of up to four times the amplitude of motion between EE and EI for correlation with the misregistered FB CT. Once a matched phase of the FB CT was determined, FB CT was deformed to a pseudo CT at the EE phase (DIR CT). DIR CT was compared with the ground truth DDG CT for AC and localization of the DDG PET.ResultsBetween DDG PET/FB CT and DDG PET/DIR CT, a significant increase in ∆%SUV was observed (p < 0.01), with median values elevating from 26.7% to 42.4%. This new method was most effective for lesions ≤3 cm proximal to the diaphragm (p < 0.001) but showed decreasing efficacy as the distance increased. When FB CT was severely misregistered with DDG PET (>3 cm), DDG PET/DIR CT outperformed DDG PET/FB CT alone (p < 0.05). Even when patients showed varied breathing patterns during the PET/CT scan, DDG PET/DIR CT still surpassed the efficiency of DDG PET/FB CT (p < 0.01). Though DDG PET/DIR CT couldn't match the performance of the DDG PET/CT ground truth (42.4% vs. 53.6%, p < 0.01), it reached 84% of its quantification, demonstrating good agreement and a strong overall correlation (regression coefficient of 0.94, p < 0.0001). In some cases, anatomical distortion and blurring, and misregistration error were observed in DIR CT, rendering it still unable to correct inaccurate localization near the boundaries of two organs.ConclusionsBased on the motion model derived from gated PET data, DIR CT can significantly improve the quantification and localization of DDG PET. This approach can achieve a performance level of about 84% of the ground truth established by DDG PET/CT. These results show that self‐gated PET and DIR CT may offer an alternative clinical solution to DDG PET and FB CT for quantification without the need for additional cine‐CT imaging. DIR CT was at times inferior to DDG CT due to some distortion and blurring of anatomy and misregistration error.

Funder

National Institutes of Health

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3