Effect of cutting flute geometry of orthodontic miniscrew on cortical bone microdamage and primary stability using a human bone analog

Author:

Wijarn Sansanee123,Uezono Masayoshi1,Takakuda Kazuo4,Ogasawara Takeshi1,Techalertpaisarn Paiboon2,Moriyama Keiji1ORCID

Affiliation:

1. Department of Maxillofacial Orthognathics, Graduate School of Medical and Dental Sciences Tokyo Medical and Dental University Tokyo Japan

2. Department of Orthodontics, Faculty of Dentistry Chulalongkorn University Bangkok Thailand

3. Tokyo Medical and Dental University and Chulalongkorn University International Joint Degree Doctor of Philosophy Program in Orthodontics Tokyo Japan

4. Institute of Biomaterials and Bioengineering Tokyo Medical and Dental University Tokyo Japan

Abstract

AbstractBackgroundAlthough orthodontic miniscrews were developed to provide reliable anchorage against orthodontic traction forces, they have pervasive low stability problems. Cutting flute geometry of the screw is considered to be a key factor; however, it has not been fully investigated. Therefore, the objective of our study is to evaluate the effect of cutting flute geometry on cortical bone microdamage.Materials and methodsHuman bone analogs, 1.0 mm thick, were prepared alongside custom‐made Ti6Al4V screws. These screws, with no flutes or modified flute geometries, came in lengths of 1.2, 2.4, and 5.0 mm, each with rake angles of 0° and 20°. Each screw was inserted into a bone sample and removed while measuring the maximum insertion torque (MIT) and the maximum removal torque (MRT). The bone microdamage was evaluated using cross‐sectional surface images of human bone analogs.ResultsMRT was significantly different in all pairwise comparisons among the three flute‐length groups in each rake angle, and the 5.0‐mm‐length groups demonstrated the lowest values. Similar tendencies were found in MIT and the bone microdamage, although significant differences were not observed in all the pairwise comparisons in the flute‐length groups in each rake angle. Interestingly, the two rake angle groups in each flute‐length exhibited significant differences in MIT and the bone microdamage, but not in MRT.ConclusionFrom our investigation using custom‐made screws and human bone analog, cortical bone microdamage is affected by both flute geometries, whereas primary stability is affected by only the flute length.

Funder

Japan Agency for Medical Research and Development

Japan Society for the Promotion of Science

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3