Valgus stress knee radiographs accurately anticipate the bone resection in medial unicompartmental knee arthroplasty: Protocol validation using an image‐based robotic system

Author:

Gaggiotti Stefano12ORCID,Foissey Constant3,Rossi Valentina4,Batailler Cecile3,Gaggiotti Gabriel12,Gaggiotti Santino12,Servien Elvire35,Lustig Sebastien36

Affiliation:

1. COT Rafaela – COT Santa Fe Rafaela Santa Fe Argentina

2. Sanatorio Mayo Santa Fe Argentina

3. Department of Orthopedic Surgery and Sports Medicine, Croix‐Rousse Hospital FIFA Medical Center of Excellence Lyon France

4. A.O.U. Azienda Ospedaliera Universitaria Federico II di Napoli Napoli Italy

5. EA 7424, Interuniversity Laboratory of Human Movement Science Université Lyon 1 Lyon France

6. IFSTTAR, LBMC UMR_T9406, Université de Lyon Université Claude Bernard Lyon 1 Lyon France

Abstract

AbstractPurposeThe objective of this study was to describe a planning method for medial unicompartmental knee arthroplasty (UKA) implantation using preoperative stress radiographs to measure the thickness of tibial and femoral bone resections and to validate this method with data from an image‐based robotic surgery system. Having such method for preoperative planning would be of interest for surgeons performing UKA in order to anticipate optimal bone resection on both tibia and femoral sides.MethodsA new planning method for medial UKA based on valgus stress knee radiographs validated it with an image‐based robotic surgery system (Restoris MCK, MAKO®, Stryker Corporation) was proposed. This retrospective study involved radiographic measurements of 76 patients who underwent image‐based robotic medial UKA between April 2022 and February 2023. Preoperative anteroposterior stress radiographs of the knee were used to simulate UKA implantation. The UKA technique was based on Cartier's angle and aimed at restoring the joint line. The total dimension measured was 14 mm (8 mm for minimal tibial component and polyethylene insert + 4 mm for femoral component + 2 mm for safety laxity). Bone resections were measured in the preoperative valgus stress radiographs and then against the intraoperative bone resection data provided by the robotic system. Inter‐ and intra‐observer reliability was assessed using 25 measurements.ResultsThe mean planned tibial resection measured in the radiographs was 4.3 ± 0.4 [2.9–5.8], while the mean robotic resection was 4.2 ± 0.5 [2.7–5.8] (mean difference = 0.15 mm, 95% confidence interval [CI] [–0.27 to 0.57]). There was a strong correlation between these two values (Pearson's rank R = 0.79, p < 0.001). Intra‐ and inter‐observer reliability were also very strong (Pearson's rank R = 0.91, p < 0.001, and Pearson's rank R = 0.82, p < 0.001, respectively). The mean planned femoral bone resection measured in the radiographs was 2.7 ± 0.7 mm [1–4.5], while the mean robotic resection was 2.5 ± 0.9 [1–5] (mean difference = 0.21 mm, 95% CI [−0.66 to 1.08]). There was a strong correlation between these two values (Pearson's rank R = 0.82, p < 0.001). Intra‐ and inter‐observer reliability were also strong (Pearson's rank R = 0.88, p < 0.001, and Pearson's rank R = 0.84, p < 0.001, respectively).ConclusionThis study describes and validates with robotic information a simple and reproducible preoperative planning method to determine femoral and tibial bone resection for medial UKA implantation using antero‐posterior valgus stress knee radiographs, leaving a medial safety laxity of 2 mm. It represents a very valuable contribution to the understanding of UKA principles, which can serve to extend its indications and increase reproducibility of the surgical technique.Level of EvidenceIII. Retrospective cohort study.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3