Study of compatibility between a 3T MR system and detector modules for a second‐generation RF‐penetrable TOF‐PET insert for simultaneous PET/MRI

Author:

Dong Qian1,Adams Zander1,Watkins Ronald D.1,Lee Brian J.12,Chang Chen‐Ming1,Sacco Ilaria1,Levin Craig S.1

Affiliation:

1. Molecular Imaging Instrumentation Laboratory Department of Radiology Stanford University Stanford California USA

2. Department of Mechanical Engineering Sungkyunkwan University Suwon South Korea

Abstract

AbstractBackgroundSimultaneous positron emission tomography/magnetic resonance imaging (PET/MRI) has shown promise in acquiring complementary multiparametric information of disease. However, designing these hybrid imaging systems is challenging due to the propensity for mutual interference between the PET and MRI subsystems. Currently, there are integrated PET/MRI systems for clinical applications. For neurologic imaging, a brain‐dedicated PET insert provides superior spatial resolution and sensitivity compared to body PET scanners.PurposeOur first‐generation prototype brain PET insert (“PETcoil”) demonstrated RF‐penetrability and MR‐compatibility. In the second‐generation PETcoil system, all analog silicon photomultiplier (SiPM) signal digitization is moved inside the detectors, which results in substantially better PET detector performance, but presents a greater technical challenge for achieving MR‐compatibility. In this paper, we report results from MR‐compatibility studies of two fully assembled second‐generation PET insert detector modules.MethodsWe studied the effect of the presence of the two second‐generation TOF‐PET insert detectors on parameters that affect MR image quality and evaluated TOF‐PET detector performance under different MRI pulse sequence conditions.ResultsWith the presence of operating PET detectors, no RF noise peaks were induced in the MR images, but the relative average noise level was increased by 15%, which led to a 3.1 to 4.2‐dB degradation in MR image signal‐to‐noise ratio (SNR). The relative homogeneity of MR images degraded by less than 1.5% with the two operating TOF‐PET detectors present. The reported results also indicated that ghosting artifacts (percent signal ghosting (PSG) ⩽ 1%) and MR susceptibility artifacts (0.044 ppm) were insignificant. The PET detector data showed a relative change of less than 5% in detector module performance between running outside and within the MR bore under different MRI pulse sequences except for energy resolution in EPI sequence (13% relative difference).ConclusionsThe PET detector operation did not cause any significant artifacts in MR images and the performance and time‐of‐flight (TOF) capability of the former were preserved under different tested MR conditions.

Funder

National Institutes of Health

Publisher

Wiley

Subject

General Medicine

Reference31 articles.

1. The potential of PET/MR for brain imaging

2. Feasibility of simultaneous PET/MR of the carotid artery: first clinical experience and comparison to PET/CT;Ripa RS;Am J Nucl Med Mol Imaging,2013

3. Simultaneous PET/MR head–neck cancer imaging: Preliminary clinical experience and multiparametric evaluation

4. HammerBE.NMR‐PET scanner apparatus. US patent 4 939 464.1990.

5. Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献