Implementation of optically simulated luminescent dosimeter for quality control of gamma ray dose of an accelerator‐based neutron source

Author:

Hu Naonori12ORCID,Nakamura Taiki3,Kataura Ryusuke3,Suga Keita3,Mukawa Tetsuya3,Akita Kazuhiko1,Sasaki Akinori1,Nojiri Mai4ORCID,Matsubayashi Nishiki2,Takata Takushi2,Tanaka Hiroki2,Nihei Keiji15,Ono Koji1

Affiliation:

1. Osaka Medical and Pharmaceutical University Kansai BNCT Medical Center Osaka Japan

2. Institute for Integrated Radiation and Nuclear Science Kyoto University Osaka Japan

3. Sumitomo Heavy Industries, Ltd. Tokyo Japan

4. Graduate School of Engineering Kyoto University Kyoto Japan

5. Osaka Medical and Pharmaceutical University Hospital Department of Radiation Oncology Osaka Japan

Abstract

AbstractBackgroundNeutron beams utilized for performing BNCT are composed of a mixture of neutrons and gamma rays. Although much of the dose delivered to the cancer cells comes from the high LET particles produced by the boron neutron capture reaction, the dose delivered to the healthy tissues from unwanted gamma rays cannot be ignored. With the increase in the number of accelerators for BNCT, a detector system that is capable of measuring gamma ray dose in a mixed neutron/gamma irradiation field is crucial. Currently, BeO TLDs encased in quartz glass are used to measure gamma ray dose in a BNCT irradiation field. However, this type of TLD is no longer commercially available. A replacement dosimetry system is required to perform the recommended ongoing quality assurance of gamma ray measurement for a clinical BNCT system.PurposeThe purpose of this study is to evaluate the characteristics of a BeO OSLD detector system under a mixed neutron and gamma ray irradiation field and to assess the suitability of the system for routine quality assurance measurements of an accelerator‐based BNCT facility.MethodsThe myOSLD system by RadPro International GmbH was evaluated using the accelerator‐based neutron source designed for clinical BNCT (NeuCure BNCT system). The readout constancy, linearity, dose rate effect, and fading effect of the OSLD were evaluated. Free‐in‐air and water phantom measurements were performed and compared with the TLD results and Monte Carlo simulation results. The PHITS Monte Carlo code was used for this study.ResultsThe readout constancy was found to be stable over a month‐long period and similar to the TLD results. The OSLD readout signal was found to be linear, with a high coefficient of determination (R2 ≥ 0.999) up to a proton charge of 3.6 C. There was no significant signal fading or dose rate dependency. The central axis depth dose and off‐axis dose profile measurements agreed with both the TLD and Monte Carlo simulation results, within one standard deviation.ConclusionThe myOSLD system was characterized using an accelerator system designed for clinical BNCT. The experimental measurements confirmed the OSLD achieved similar, if not superior to, the currently utilized dosimetry system for routine QA of an accelerator‐based BNCT system. The OSLD system would be a suitable replacement for the current TLD system for performing routine QA of gamma ray dose measurement in a BNCT irradiation field.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3