Dosimetric impact of intrafraction patient motion on MLC‐based 3D‐conformal spatially fractionated radiation therapy treatment of large and bulky tumors

Author:

Misa Josh1,Volk Alex1,Bernard Mark E.1,Clair William St.1,Pokhrel Damodar1ORCID

Affiliation:

1. Department of Radiation Medicine Medical Physics Graduate Program University of Kentucky Lexington Kentucky USA

Abstract

AbstractPurposeTo evaluate the dosimetric impact on spatially fractionated radiation therapy (SFRT) plan quality due to intrafraction patient motion via multi‐field MLC‐based method for treating large and bulky (≥8 cm) unresectable tumors.MethodsFor large tumors, a cone beam CT‐guided 3D conformal MLC‐based SFRT method was utilized with 15 Gy prescription. An MLC GTV‐fitting algorithm provided 1 cm diameter apertures with a 2 cm center‐to‐center distance at the isocenter. This generated a highly heterogeneous sieve‐like dose distribution within an hour, enabling same‐day SFRT treatment. Fifteen previously treated SFRT patients were analyzed (5 head & neck [H&N], 5 chest and lungs, and 5 abdominal and pelvis masses). For each plan, intrafraction motion errors were simulated by incrementally shifting original isocenters of each field in different x‐, y‐, and z‐directions from 1 to 5 mm. The dosimetric metrics analyzed were: peak‐to‐valley‐dose‐ratio (PVDR), percentage of GTV receiving 7.5 Gy, GTV mean dose, and maximum dose to organs‐at‐risk (OARs).ResultsFor ±1, ±2, ±3, ±4, and ±5 mm isocenter shifts: PVDR dropped by 3.9%, 3.8%, 4.0%, 4.1%, and 5.5% on average respectively. The GTV(V7.5) remained within 0.2%, and the GTV mean dose remained within 3.3% on average, compared to the original plans. The average PVDR drop for 5 mm shifts was 4.2% for H&N cases, 10% for chest and lung, and 2.2% for abdominal and pelvis cases. OAR doses also increased. The maximum dose to the spinal cord increased by up to 17 cGy in H&N plans, mean lung dose (MLD) changed was small for chest/lung, but the bowel dose varied up to 100 cGy for abdominal and pelvis cases.ConclusionDue to tumor size, location, and characteristics of MLC‐based SFRT, isocenter shifts of up to ±5 mm in different directions had moderate effects on PVDR for H&N and pelvic tumors and a larger effect on chest tumors. The dosimetric impact on OAR doses depended on the treatment site. Site‐specific patient masks, Vac‐Lok bags, and proper immobilization devices similar to SBRT/SRT setups should be used to minimize these effects.

Publisher

Wiley

Reference26 articles.

1. High‐dose spatially fractionated radiation (grid): a new paradigm in the management of advanced;Mohiuddin M;CANCERS,1999

2. Therapeutic advantage of grid irradiation for large single fractions

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3