Implementation of an ionization chamber array for linear accelerator monthly dosimetry QA

Author:

Taneja Sameer1ORCID,Barbee David L.1

Affiliation:

1. Department of Radiation Oncology New York University Langone Medical Center New York New York USA

Abstract

AbstractPurposeThe IC Profiler (ICP) manufactured by Sun Nuclear Corporation (SNC) is an ionization chamber (IC) array used for linear accelerator dosimetry measurements. Previous work characterized response of the ICP under various conditions, but there is limited work of its implementation into monthly QA measurement procedures. This work quantifies ICP accuracy and variables that affect accuracy for beam output measurements, and demonstrates feasibility of using the ICP for all recommended monthly dosimetry measurements.MethodsA total of 1985 output measurements on six Varian TrueBeam and Edge linear accelerators were performed using three ICP with quad wedges (QWs) and were compared with conventional IC measurements. The accuracy of the ICP for beam output was characterized as the difference between the ICP and IC. Variables that affect ICP accuracy, including gain settings, calibrations, and template baselining as well as machine or energy‐specific bias were investigated. Measurements of profile constancy, energy, dose rate constancy, wedge factors, and gating were performed.ResultsThe initially observed mean output difference between the ICP and IC was 0.16% (0.61%). When gain settings were optimized, the output difference accuracy improved to −0.02% (0.38%). The output accuracy of the ICP was not dependent on array, dose, temperature and pressure calibrations, or template baselining. Statistically, ICP output accuracy was dependent on machine and beam energy, but clinically, all measurements fell within 0.5% of unity. ICP measurements of energy, dose rate constancy, and wedge factors matched passing results with conventional IC in water measurements. Gating and beam profile constancy measurements demonstrated good stability using the ICP. Finally, monthly dosimetry QA using ICP was completed in an average of 33 min compared to 66 min using the IC.ConclusionThis work demonstrated the feasibility and efficiency of using the ICP, with specific considerations, as a measurement device for dosimetric linear accelerator monthly QA.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3