Affiliation:
1. Institute of Chemical Technology of Inorganic Materials Johannes Kepler University Linz Altenberger Str. 69 4040 Linz Austria
2. Bundesanstalt für Materialforschung und –prüfung (BAM) Unter den Eichen 87 12205 Berlin Germany
3. Department of Physics and Chemistry of Materials, Faculty of Medicine and Dentistry Danube Private University Steiner Landstraße 124 Krems an der Donau 3500 Austria
Abstract
A corrosion study is performed on six variations of titanium grade 5 (Ti6Al4V) samples. Samples are prepared in different conditions by variation of preanodization, postanodization, and picosecond‐laser (ps‐laser) surface treatment, while polished and anodized samples serve as reference. Microcones and nanosized periodic surface features are successfully produced on Ti6Al4V samples. The morphology and topography of the structures are visualized by scanning electron microscopy and white light interference microscopy. Furthermore, the relative electrochemically active surface area (ECSA) is determined for the ps‐laser‐treated samples. It is determined that the preanodized and laser‐treated sample has 3.5 times larger ECSA than a polished sample, and that the laser‐treated sample has 4.1 times larger area. Moreover, Tafel analysis is performed to determine the corrosion properties of the samples. It is shown that the corrosion resistance improves for both laser‐structured samples after the anodization. To further study the surface of the samples, electrochemical impedance spectroscopy measurements are conducted. The study indicates that the ps‐laser‐treated and anodized Ti6Al4V is suitable to be used for the fabrication of bone screws and plates due to its improved corrosion resistance as compared to nonanodized samples.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献