Flexible Thin‐Film Neural Electrodes with Improved Conformability for ECoG Measurements and Electrical Stimulation

Author:

Imai Ayano1,Takahashi Shunta1,Furubayashi Sho1,Mizuno Yosuke1,Sonoda Masaki2,Miyazaki Tomoyuki3,Miyashita Eizo1,Fujie Toshinori14ORCID

Affiliation:

1. School of Life Science and Technology Tokyo Institute of Technology B‐50, 4259 Nagatsuta‐cho, Midori‐ku Yokohama 226‐8501 Japan

2. Department of Neurosurgery Yokohama City University Graduate School of Medicine 3–9 Fukuura, Kanazawa‐ku Yokohama 236‐0004 Japan

3. Department of Physiology Yokohama City University Graduate School of Medicine 3–9 Fukuura, Kanazawa‐ku Yokohama 236‐0004 Japan

4. Living Systems Materialogy (LiSM) Research Group International Research Frontiers Initiative (IRFI) Tokyo Institute of Technology B‐50, 4259 Nagatsuta‐cho, Midori‐ku Yokohama 226‐8501 Japan

Abstract

Neural electrodes for electrocorticography (ECoG) recording and electrical stimulation are used for diagnosis and treatment of epilepsy, which are temporarily attached to the surface of cerebral cortex within the subdural space. However, conventional electrodes have a mechanical mismatch with the surface curvature of the brain cortex. Thus, it is necessary to develop a thin and flexible ECoG electrode to overcome the mechanical mismatch with cortex tissue and achieve long‐term ECoG measurement. Herein, a flexible thin‐film electrode is reported with a thickness of ≈8 µm by exploiting printed electronics. A simple fabrication method of conductive wiring is proposed by inkjet printing Au nanoink on a flexible elastomeric thin film consisting of polystyrene‐block‐polybutadiene‐block‐polystyrene (SBS). The conductive wiring printed on the SBS thin film is encapsulated by another SBS thin film as an insulation layer, with laser‐processed micropatterns. The flexible thin‐film electrode is implanted on the cortical surface of rats and used for in vivo ECoG recording and electrical stimulation without the occurrence of severe inflammatory reactions after 6 weeks of implantation. The flexible electrode with 35 ECoG channels visualized the epileptiform activity in a drug‐induced epilepsy rat model, which demonstrates the potential application for the management of intractable epilepsy.

Funder

Japan Agency for Medical Research and Development

Japan Science and Technology Agency

Japan Society for the Promotion of Science

Publisher

Wiley

Subject

Industrial and Manufacturing Engineering,Mechanics of Materials,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3