Analysis of histidine‐tagged recombinant proteins from nickel and copper coated surfaces by direct electrospray ionization and desorption electrospray ionization mass spectrometry

Author:

Javanshad Roshan1,Taylor Christopher James1,Delavari Niusha1,Barkman Todd J.2,Stull Frederick1,Venter Andre R.1ORCID

Affiliation:

1. Department of Chemistry Western Michigan University Kalamazoo MI USA

2. Department of Biological Sciences Western Michigan University Kalamazoo MI USA

Abstract

RationalePurification of recombinant proteins is a necessary step for functional or structural studies and other applications. Immobilized metal affinity chromatography is a common recombinant protein purification method. Mass spectrometry (MS) allows for confirmation of identity of expressed proteins and unambiguous detection of enzymatic substrates and reaction products. We demonstrate the detection of enzymes purified on immobilized metal affinity surfaces by direct or ambient ionization MS, and follow their enzymatic reactions by direct electrospray ionization (ESI) or desorption electrospray ionization (DESI).MethodsA protein standard, His‐Ubq, and two recombinant proteins, His‐SHAN and His‐CS, expressed in Escherichia coli were immobilized on two immobilized metal affinity systems, Cu–nitriloacetic acid (Cu‐NTA) and Ni‐NTA. The proteins were purified on surface, and released in the ESI spray solvent for direct infusion, when using the 96‐well plate form factor, or analyzed directly from immobilized metal affinity‐coated microscope slides by DESI‐MS. Enzyme activity was followed by incubating the substrates in wells or by depositing substrate on immobilized protein on coated slides for analysis.ResultsSmall proteins (His‐Ubq) and medium proteins (His‐SAHN) could readily be detected from 96‐well plates by direct infusion ESI, or from microscope slides by DESI‐MS after purification on surface from clarified E. coli cell lysate. Protein oxidation was observed for immobilized proteins on both Cu‐NTA and Ni‐NTA; however, this did not hamper the enzymatic reactions of these proteins. Both the nucleosidase reaction products for His‐SAHN and the methylation product of His‐CS (theobromine to caffeine) were detected.ConclusionsThe immobilization, purification, release and detection of His‐tagged recombinant proteins using immobilized metal affinity surfaces for direct infusion ESI‐MS or ambient DESI‐MS analyses were successfully demonstrated. Recombinant proteins were purified to allow identification directly out of clarified cell lysate. Biological activities of the recombinant proteins were preserved allowing the investigation of enzymatic activity via MS.

Funder

National Science Foundation

Publisher

Wiley

Subject

Organic Chemistry,Spectroscopy,Analytical Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3