Abstract

AbstractObjectiveIdentification of anatomical landmarks is essential for interpretation of video fluoroscopic swallow studies (VFSS). This investigation sought to confirm the location of essential laryngeal landmarks and determine clinician accuracy in structure identification on VFSS.MethodsA single human cadaver was used to generate unmarked standard lateral and anterior–posterior (AP) fluoroscopic images. Essential laryngeal structures (e.g., true vocal fold, arytenoid) were directly identified using a guidewire placed through an endoscope while obtaining corresponding marked fluoroscopic images. Licensed clinicians (speech‐language pathologists [SLP], laryngologists) and trainees (otolaryngology residents, SLP clinical fellows [CF]) identified 18 structures (9 lateral, 9 AP) on unmarked images. Answers were compared to corresponding marked images. The percentage of accurate identification was calculated for each clinician and then compared between groups using t‐tests.ResultsTwenty‐four individuals (10 SLPs, 1 CF, 9 residents, 4 laryngologists) from six institutions completed structure identification. Mean overall accuracy was 41.7 ± 13.0% (range 18.8–68.8%). There were no significant differences in mean overall accuracy between trainees (41.9 ± 12.9%) and clinicians (42.0 ± 13.1%), p = .97, or between SLPs (45.5 ± 12.8%) and physicians (38.9 ± 12.3%), p = .22. On average, participants were significantly more accurate identifying structures on lateral view (53.1 ± 16.1%) than AP (27.3 ± 22.8%), p < .001. Less than half of participants accurately identified the laryngeal ventricle, cricoid, epiglottic petiole, and the anterior commissure on lateral view.ConclusionsThe ability of certified clinicians and trainees to correctly identify essential anatomic landmarks on swallowing fluoroscopy may be poor. Future work is needed to identify how we can train clinicians on more accurate identification of essential anatomic structures on swallowing fluoroscopy.Level of Evidence: NA.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3