Individually tailored spatial–spectral pulsed CEST MRI for ratiometric mapping of myocardial energetic species at 3T

Author:

Ayala Cindy1,Luo Huiwen2ORCID,Godines Kevin1,Alghuraibawi Wissam1,Ahn Sinyeob3,Rehwald Wolfgang4,Grissom William A.5,Vandsburger Moriel H.1ORCID

Affiliation:

1. Department of Bioengineering University of California, Berkeley Berkeley California USA

2. Department of Biomedical Engineering Vanderbilt University Nashville Tennessee USA

3. MR R&D Collaborations Siemens Medical Solutions San Francisco California USA

4. MR R&D Collaborations Siemens Medical Solutions Durham North Carolina USA

5. Department of Biomedical Engineering, Case School of Engineering Case Western Reserve University Cleveland Ohio USA

Abstract

AbstractPurposeCEST MRI has been used to probe changes in cardiac metabolism via assessment of CEST contrast from Cr. However, B1 variation across the myocardium leads to spatially variable Cr CEST contrast in healthy myocardium.MethodsWe developed a spatial–spectral (SPSP) saturation pulsed CEST protocol to compensate for B1 variation. Flip angle maps were used to individually tailor SPSP pulses comprised of a train of one‐dimensional spatially selective subpulses selective along the principal B1 gradient dimension. Complete Z‐spectra in the hearts of (n = 10) healthy individuals were acquired using conventional Gaussian saturation and SPSP schemes and supported by phantom studies.ResultsIn simulations, the use of SPSP pulses reduced the average SD of the effective saturation B1 values within the myocardium (n = 10) from 0.12 ± 0.02 μT to 0.05 ± 0.01 μT (p < 0.01) and reduced the average SD of Cr CEST contrast in vivo from 10.0 ± 4.3% to 6.1 ± 3.5% (p < 0.05). Results from the hearts of human subjects showed a significant reduction of CEST contrast distribution at 2 ppm, as well as amplitude, when using SPSP saturation. Corresponding phantom experiments revealed PCr‐specific contrast generation at body temperature when SPSP saturation was used but combined PCr and Cr contrast generation when Gaussian saturation was used.ConclusionThe use of SPSP saturation pulsed CEST resulted in PCr‐specific contrast generation and enabled ratiometric mapping of PCr to total Cr CEST contrast in the human heart at 3T.

Funder

Division of Graduate Education

National Institutes of Health

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3