Technical note: Accuracy and precision of T2 and T2* with a gradient‐echo spin‐echo (GESE) sequence for cardiac imaging

Author:

Huang Qi12,Mendes Jason1,Adluru Ganesh12,DiBella Edward12

Affiliation:

1. Utah Center for Advanced Imaging Research (UCAIR) Department of Radiology and Imaging Sciences University of Utah Salt Lake City Utah USA

2. Department of Biomedical Engineering University of Utah Salt Lake City Utah USA

Abstract

AbstractBackgroundThe use of a gradient echo spin echo (GESE) method to obtain rapid T2 and T2* estimation in the heart has been proposed. The effect of acquisition parameter settings on T2 and T2* bias and precision have not been investigated in depth.PurposeTo understand factors impacting the quantification of T2 and T2* values with a gradient echo spin echo (GESE) method using echo planar imaging (EPI) readouts in a reduced field of view acquisition.MethodsThe GESE method is implemented with a reduced field‐of‐view using an outer volume suppression (OVS) technique to minimize the time for multi‐echo EPI readouts. The number of EPI readouts (images) for the GESE is optimized using Cramer‐Rao Lower Bound (CRLB) and Monte Carlo simulations with a nonlinear least‐square (NLLS) estimator. The SNR requirements were studied using the latter simulation method for a selected range of T2 and T2* values and T2/T2* ratios. Two healthy control subjects were imaged with the proposed GESE sequence and evaluated with the NLLS estimation method. In addition, the proposed OVS method was compared with a saturation bands OVS method in one subject. Clinical T2 and T2* mappings were used as the reference.ResultsThe optimal number of EPI readouts is five and the performance is slightly better when the refocusing pulse is placed between the 2nd and 3rd readouts. The SNR requirement for achieving a target bias < 1 ms and standard deviation (SD) < 5 ms is more demanding when T2/T2* ratio increases. The minimum SNR requirement in the GESE acquisition should vary from 6 to 20 depending on specific myocardial T2 and T2* values at 3T. The T2 and T2* estimates using the proposed OVS method and the saturation bands OVS method are both similar to the reference.ConclusionThe GESE sequence with five EPI readouts is a feasible and efficient technique that can estimate T2 and T2* values in the septal myocardium within a heartbeat when the SNR requirement can be satisfied.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3