Diastolic exercise stress testing in heart failure with preserved ejection fraction: The DEST‐HF study

Author:

Wernhart Simon1,Goertz Annika1,Hedderich Juergen2,Papathanasiou Maria1,Hoffmann Julia1,Rassaf Tienush1,Luedike Peter1ORCID

Affiliation:

1. Department of Cardiology and Vascular Medicine University Hospital Essen, University Duisburg‐Essen, West German Heart and Vascular Center Essen Germany

2. Medistat‐Biomedical Statistics Medistat GmbH Krummwisch Germany

Abstract

AbstractAimsPulmonary capillary wedge pressure (PAWP) ≥25 mmHg during bicycle ergometry is recommended to uncover occult heart failure with preserved ejection fraction. We hypothesized that PAWP increase would differ in available diastolic stress tests and that the margin of PAWP ≥25 mmHg would only be reliably achieved through ergometry.Methods and resultsWe conducted a prospective, single‐arm study in patients with an intermediate risk for heart failure with preserved ejection fraction according to the ESC HFA‐PEFF score. A total of 19 patients underwent four stress test modalities in randomized order: leg raise, fluid challenge, handgrip, and bicycle ergometry. The primary outcome was the difference (Δ) between resting and exercise PAWP in each modality. Secondary outcomes were differences (Δ) in mean pulmonary artery pressure (mPAP), cardiac output (CO), as well as the ratios between mPAP and PAWP to CO. Compared to resting values, passive leg raise (Δ7.7 ± 8.0 mmHg, p = 0.030), fluid challenge (Δ9.2 ± 6.4 mmHg, p = 0.003), dynamic handgrip (Δ9.6 ± 7.5 mmHg, p = 0.002), and bicycle ergometry (Δ22.3 ± 5.0 mmHg, p < 0.001) uncovered increased PAWP during exercise. Amongst these, bicycle ergometry also demonstrated the highest ΔmPAP (27.2 ± 7.1 mmHg, p < 0.001), ΔCO (3.3 ± 2.6 L/min, p < 0.001), ΔmPAP/CO ratio (2.3 ± 2.0 mmHg/L/min, p < 0.001), and ΔPAWP/CO ratio (2.2 ± 1.4 mmHg/L/min, p < 0.001) compared to other modalities. PAWP ≥25 mmHg was only reliably achieved in bicycle ergometry (31.1 ± 3.9 mmHg). In all other modalities only 10.5% of patients achieved PAWP ≥25 mmHg (handgrip 18.4 ± 6.6 mmHg, fluid 18.1 ± 5.6 mmHg, leg raise 16.5 ± 7.0 mmHg).ConclusionsWe demonstrate that bicycle ergometry exhibits a distinct haemodynamic response with higher increase of PAWP compared to other modalities. This finding needs to be considered for valid detection of exercise PAWP ≥25 mmHg when non‐bicycle tests remain inconclusive.

Funder

Deutsche Forschungsgemeinschaft

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3