Abstract

AbstractPurposeRespiratory‐correlated 4D‐MRI may provide motion characteristics for radiotherapy but is susceptible to irregular breathing. This study investigated the effectiveness of visual biofeedback (VBF) guidance for breathing regularization during 4D‐MRI acquisitions on an MR‐linac.MethodsA simultaneous multislice‐accelerated 4D‐MRI sequence was interleaved with a one‐dimensional respiratory navigator (1D‐RNAV) in 10 healthy volunteers on a 1.5T Unity MR‐linac (Elekta AB, Stockholm, Sweden). Volunteer‐specific breathing amplitudes and periods were derived from the 1D‐RNAV signal obtained during unguided 4D‐MRI acquisitions. These were used for the guidance waveform, while the 1D‐RNAV positions were overlayed as VBF. VBF effectiveness was quantified by calculating the change in coefficient of variation () for the breathing amplitude and period, the position SD of end‐exhale, end‐inhale and midposition locations, and the agreement between the 1D‐RNAV signals and guidance waveforms. The 4D‐MRI quality was assessed by quantifying amounts of missing data.ResultsVBF had an average latency of 520 ± 2 ms. VBF reduced median breathing variations by 18% to 35% (amplitude) and 29% to 57% (period). Median position SD reductions ranged from −3% to 35% (end‐exhale), 29% to 38% (end‐inhale), and 25% to 37% (midposition). Average differences between guidance waveforms and 1D‐RNAV signals were 0.0 s (period) and +1.7 mm (amplitude). VBF also decreased the median amount of missing data by 11% and 29%.ConclusionA VBF system was successfully implemented, and all volunteers were able to adapt to the guidance waveform. VBF during 4D‐MRI acquisitions drastically reduced breathing variability but had limited effect on missing data in respiratory‐correlated 4D‐MRI.

Funder

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3