The accuracy of preoperative implant size prediction achieved by digital templating in total knee arthroplasty is not affected by the quality of lateral knee radiographs

Author:

Pichler Lorenz1ORCID,Klein Leonhard1,Perka Carsten F.1ORCID,Gwinner Clemens1ORCID,El Kayali Moses K. D.1

Affiliation:

1. Charité—Universitätsmedizin Berlin Centrum für Muskuloskeletale Chirurgie Berlin Germany

Abstract

AbstractBackgroundDigital templating software can be used for preoperative implant size prediction in total knee arthroplasty (TKA). However, the accuracy of its prediction is reported to be low, and the impact of radiograph quality is unclear.PurposeTo investigate on the application of lateral knee radiograph quality criteria for knee rotation (KR) and knee abduction/adduction (KA) and their impact on the accuracy of final implant size prediction achieved by preoperative digital templating for TKA.MethodsA total of 191 radiographs of patients undergoing TKA were allocated into four groups according to their KR as measured at the posterior femoral condyles and their KA as measured at the distal femoral condyles on lateral knee radiographs: group A (KR ≤ 5 mm, KA ≤ 5 mm), B1 (KR > 5 mm, KA ≤ 5 mm), B2 (KR ≤ 5 mm, KA > 5 mm) and B3 (KR > 5 mm, KA > 5 mm). Preoperative templating of femoral and tibial implant size using digital templating software was carried out by two observers. Correlation coefficients (CCs) between planned and final implant size, percentage of cases with planned to final size match as well as percentage of cases within ±1 and ±2 of planned to final size were reported according to groups.ResultsGroup A showed the highest percentage of cases with matching planned to final femoral implant size (45%) and the highest percentage of cases with ±1 planned to final implant size (86%) as compared to B1 (match 28%, ±1 84%), B2 (match 41%, ±1 84%) and B3 (match 35%, ±1 78%). CCs for planned to final implant size were reported at >0.75 in all groups. No statistically significant difference in the CCs of planned to final implant size amongst groups was found.ConclusionThe accuracy of implant size prediction achieved by preoperative digital templating for TKA is neither affected by KR nor KA on lateral knee radiographs.Level of evidenceLevel III.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3