Measuring mantled howler monkey (Alouatta palliata) testes via parallel laser photogrammetry: Expanding the use of noninvasive methods

Author:

Ehrie Austen J.12ORCID,Iruri‐Tucker Alec A.2,Lord Yasmin B.3,Williamson Heidi G.4,Hunt Kevin D.23,Polly P. David25,Fitzpatrick Courtney L.1,Wasserman Michael D.23

Affiliation:

1. Department of Biology Texas A&M University College Station Texas USA

2. Center for the Integrative Study of Animal Behavior Indiana University Bloomington Indiana USA

3. Department of Anthropology Indiana University Bloomington Indiana USA

4. Department of Ecology and Conservation Biology Texas A&M University College Station Texas USA

5. Department of Geology Indiana University Bloomington Indiana USA

Abstract

AbstractParallel laser photogrammetry (PLP), which consists of attaching two or three parallel laser beams at a known inter‐beam distance to a camera, can be used to collect morphological measurements of organisms noninvasively. The lasers project onto the photo being taken, and because the inter‐beam distance is known, they act as a scale for image analysis programs like ImageJ. Traditionally, this method has been used to measure larger morphological traits (e.g., limb length, crown‐rump length) to serve as proxies for overall body size, whereas applications to smaller anatomical features remain limited. To that end, we used PLP to measure the testes of 18 free‐living mantled howler monkeys (Alouatta palliata) at La Selva Biological Station, Costa Rica. We tested whether this method could reliably measure this relatively small and globular morphology, and whether it could detect differences among individuals. We tested reliability in three ways: within‐photo (coefficient of variation [CV] = 4.7%), between‐photo (CV = 5.5%), and interobserver (intraclass correlation = 0.92). We found an average volume of 36.2 cm3 and a range of 16.4–54.4 cm3, indicating variation in testes size between individuals. Furthermore, these sizes are consistent with a previous study that collected measurements by hand, suggesting that PLP is a useful method for making noninvasive measurements of testes.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3