General principle and optimization of magneto‐acousto‐electrical tomography based on image distortion evaluation

Author:

Li Peixia1,Chen Wei1,Guo Gepu1,Tu Juan2,Zhang Dong2,Ma Qingyu1

Affiliation:

1. School of Computer and Electronic Information Nanjing Normal University Nanjing China

2. Institute of Acoustics Nanjing University Nanjing China

Abstract

AbstractBackgroundAs a novel non‐invasive multi‐physics imaging methodology, the magneto‐acousto‐electrical (MAE) technology is capable of detecting electric conductivity changes for biological tissues, exhibiting prosperous perspectives in medical applications. However, the acoustic beam was often simplified to a straight line or a focused one, being perpendicular to layered boundaries of tissues in previous studies. Linear‐scanning measurements were carried out to reconstruct B‐mode MAE images for layered models without considering the radiation pattern of transducers. Obvious image distortions in both shape and brightness were observed in experiments without any reasonable explanation.PurposeThis study aims to establish a general physical model for MAE measurements and solve the problem of B‐mode image distortion, and hence provide theoretical and technical supports for the improvement of MAE imaging in practical applications.MethodsBy considering the radiation pattern of actual transducers and the inclined angle of electric conductivity boundaries, a general principal of MAE measurements applicable for objects of arbitrary shapes is proposed based on the theories of acoustic radiation, Hall Effect and electrical detection. The influences of inclined conductivity boundaries and transducer directivities are numerically analyzed with Matlab programming and also demonstrated by experimental measurements. To evaluate the degree of B‐mode image distortion, the deformation length (3 dB amplitude decrease) of approximate straight lines for a circular model is defined as L = dtan(βm/2), with d and βm being the measurement distance and the half radiation angle of the main‐lobe, respectively. The rotary‐scanning‐based MAE tomography (MAET) is employed to reduce the image distortion, and the rotation angle step is further optimized based on the criterion of the boundary radius fluctuation coefficient <0.01 mm.ResultsThe experimental results of MAE signals and B‐mode images as well as MAETs show good agreements with simulations. It is demonstrated that, as the increase of the inclined angle, the MAE decreases rapidly with an extended time interval and reaches the 20 dB amplitude decrease when the angle exceeds 12°. Meanwhile, the deformation length of B‐mode MAE imaging increases with the increase of the radiation angle for the transducer with a weaker radiation pattern, and hence results in a more serious image distortion. A smaller rotation angle step should be adopted to the MAET system with a longer deformation length, and the optimized maximum angle step of 12° is also achieved for the omnidirectional radiation of point sources with a long deformation length.ConclusionThe image distortion is originated from the amplitude decrease, the time shift and the time interval expansion of MAE signals introduced by the deformation length and the incident angle. The favorable results demonstrate that the fast high‐resolution imaging can be accomplished by the minimum rotations of the rotary‐scanning‐based MAET using an actual transducer, and also provide an optimized scheme for the rotary‐based MAET without scanning using a linear array of point sources.

Funder

National Natural Science Foundation of China

Natural Science Foundation of Jiangsu Province

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3