Prediction of thermal efficiency of double pass solar air heater having discrete multi V and staggered ribs

Author:

Ravi Ravi Kant1,Kumar Sanjay1,Kumar Mukesh2,Kumar Manoj3,Verma Vikas4ORCID,Alam Tabish5,Yadav Anil Singh6,Sharma Abhishek7

Affiliation:

1. Mechanical Engineering Department Dr. B.R. Ambedkar 4National Institute of Technology Jalandhar Punjab India

2. Mechanical Engineering Department Indian Institute of Science and Technology, Shibpur Howrah West Bengal India

3. Mechanical Engineering Department National Institute of Technology Srinagar J&K India

4. Department of Energy Tezpur University Tezpur Napam Assam India

5. CSIR‐Central Building Research Institute Roorkee India

6. Department of Mechanical Engineering Bakhtiyarpur College of Engineering (Science, Technology and Technical Education Department, Govt. of Bihar), Bakhtiyarpur Patna Bihar India

7. Department of Mechanical Engineering Government Engineering College (Department of Higher and Technical Education, Govt. of Jharkhand) Palamu Jharkhand India

Abstract

AbstractThis manuscript endeavors to elucidate a comprehensive analysis for the assessment of thermal efficiency in double pass solar air collectors augmented with fabricated roughness, instrumental in the generation of heated air for applications in heating and drying. The analytical procedure delineates comparisons between a smooth and a double‐sided, roughened absorber, characterized by discrete, multi V and staggered configurations of roughness. The analysis was performed for different roughness parameters including relative roughness width (W/w) from 4 to 8 and relative staggered rib size (r/e) from 1 to 4 and relative rib pitch (p′/p) from 0.2 to 0.8 while other parameters were kept constant. The research scrutinizes the impact of a constellation of parameters: the temperature rise coefficient (ΔT/I, varying between 0.002 and 0.02 K‐m²/W), Reynolds number (Re, spanning 2000–20,000), solar irradiance (I, ranging from 600 to 1000 W/m²), and the geometric variables of the artificial roughness, on both the thermal efficiency and efficiency enhancement factor of the collector. The study revealed that the roughened collector exhibits higher thermal efficiency compared to smooth collector for a similar condition. The extreme enhancement in thermal efficiency of the collector with roughness has been found to be 56.75% more than nonroughened collector for Re = 2000. A further observation was made that thermal efficiency has increased sharply for lower flow rate (Re < 10,000) whereas for higher flow rates (Re > 10,000), this increase becomes nearly asymptotic. In addition, the efficiency enhancement factor has also been found to increase with an increase in ΔT/I. A peak value of 2.321 has been found to be obtained for the efficiency enhancement factor for ΔT/I = 0.02 K‐m2/W and I = 1000 W/m2 as a result of the studies conducted.