Cyclic and torsional fatigue resistance of a new rotary file on a rotary and reciprocating motion

Author:

Só Gabriel Barcelos1ORCID,Siocheta Giovana1,Calefi Pedro2,Alcalde Murilo2,Vivan Rodrigo Ricci2ORCID,Duarte Marco Antônio H.2ORCID,Só Marcus Vinicius Reis1ORCID,da Rosa Ricardo Abreu1ORCID

Affiliation:

1. Department of Conservative Dentistry, School of Dentistry Rio Grande do Sul Federal University (UFRGS) Porto Alegre Brazil

2. Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry University of São Paulo São Paulo Brazil

Abstract

AbstractThis study evaluated the cyclic and torsional fatigue resistance of a new nickel‐titanium (Flat File 25.04) instrument on the continuous and reciprocating motion. Sixty instruments of the ProDesign Logic2 25.03 and 25.05 (Easy Equipamentos Odontológicos, Belo Horizonte, Brazil), and MK Flat File 25.04 (n = 20) (MK Life, Porto Alegre, Brazil) were used. For the cyclic fatigue test, an artificial stainless steel simulated canal with an angle of 60° and a radius of curvature of 5 mm located 5 mm from its tip was used. The torque and rotation angle at the instruments' failure on the torsional fatigue test was based on the ISO 3630‐1 protocol, in which the 3 mm tip of each instrument was fixed and connected to an electric motor and a load cell. The fractured surface of each fragment was examined by scanning electron microscopy. Data were analyzed using a 1‐way analysis of variance and Tukey's test with a significance level of 5%. Flat File 25.04 had lower cyclic fatigue in both kinematics than the Logic instruments (p < .05). Reciprocating motion improved the cyclic fatigue of the tested instruments (p < .05). Flat File 25.04 had similar torque to Logic2 25.05 (p > .05), and both were superior to Logic2 25.03 (p < .05). The angular deflection values were different for the three tested instruments (p < .05), in the decreasing order: Logic2 25.03, 25.05, and Flat File 25.04. Flat File presented good resistance to cyclic and torsional fatigue resistance. Reciprocating motion improved the cyclic fatigue resistance of the instruments and can be considered when using programmable motors.Research Highlights Scanning electron microscopy evaluation of different endodontic rotary file and fatigue resistance tests.

Publisher

Wiley

Subject

Medical Laboratory Technology,Instrumentation,Histology,Anatomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3