Reproducibility of 3D pH‐weighted chemical exchange saturation transfer contrast in the healthy cervical spinal cord

Author:

Cronin Alicia E.12ORCID,Liebig Patrick3,Detombe Sarah A.4,Duggal Neil14,Bartha Robert12

Affiliation:

1. Department of Medical Biophysics, Schulich School of Medicine & Dentistry Western University London Ontario Canada

2. Centre for Functional and Metabolic Mapping, Robarts Research Institute, Schulich School of Medicine & Dentistry Western University London Ontario Canada

3. Siemens Healthcare GmbH Erlangen Germany

4. Department of Clinical Neurological Sciences London Health Sciences Centre London Ontario Canada

Abstract

Spinal cord ischemia and hypoxia can be caused by compression, injury, and vascular alterations. Measuring ischemia and hypoxia directly in the spinal cord noninvasively remains challenging. Ischemia and hypoxia alter tissue pH, providing a physiologic parameter that may be more directly related to tissue viability. Chemical exchange saturation transfer (CEST) is an MRI contrast mechanism that can be made sensitive to pH. More specifically, amine/amide concentration independent detection (AACID) is a recently developed endogenous CEST contrast that has demonstrated sensitivity to intracellular pH at 9.4 T. The goal of this study was to evaluate the reproducibility of AACID CEST measurements at different levels of the healthy cervical spinal cord at 3.0 T incorporating B1 correction. Using a 3.0 T MRI scanner, two 3D CEST scans (saturation pulse train followed by a 3D snapshot gradient‐echo readout) were performed on 12 healthy subjects approximately 10 days apart, with the CEST volume centered at the C4 level for all subjects. Scan–rescan reproducibility was evaluated by examining between and within‐subject coefficients of variation (CVs) and absolute AACID value differences. The C4 level of the spinal cord demonstrated the lowest within‐subject CVs (4.1%–4.3%), between‐subject CVs (5.6%–6.3%), and absolute AACID percent difference (5.8–6.1%). The B1 correction scheme significantly improved reproducibility (adjusted p‐value = 0.002) compared with the noncorrected data, suggesting that implementing B1 corrections in the spinal cord is beneficial. It was concluded that pH‐weighted AACID measurements, incorporating B1‐inhomogeneity correction, were reproducible within subjects along the healthy cervical spinal cord and that optimal image quality was achieved at the center of the 3D CEST volume.

Funder

Natural Sciences and Engineering Research Council of Canada

Canada First Research Excellence Fund

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3