Abstract

AbstractQuality is an indispensable requirement in medical laboratories, where controls are performed at different phases of the laboratory processes. In the following, we consider the internal quality control activities during the analytical phase of medical laboratories for verifying the test results prior to their release. To monitor the measurement process for errors in the test results, one approach that is considerably attracting the health professionals is patient‐based real‐time quality control. In this respect, real‐time patient test results are monitored, commonly by implementing the Moving Average (MA) control chart with truncation limits. A usual practice is the use of truncation limits to exclude abnormal patient test results from the MA calculations. However, an open issue in the literature is how to determine the width of the truncation limits and the window size in the MA calculations. Furthermore, the distributions of the test results are often nonnormal and difficult to model by personnel having insufficient training in statistics. Consequently, robustness of the performance of the MA control chart to non‐normal distributions of test results is another open topic in the literature. In this study, a detailed robustness analysis is performed by considering various distributions having different shapes. Performance of several MA control chart designs constructed by altering the truncation limits and window sizes are investigated. Based on our simulation results with selected distributions, we conclude that the truncation limits should not be used and a window size of 20 is recommended. Under such a setting, the MA control chart performs similar to its intended performance in terms of false alarms and in detecting systematic errors, hence being robust to non‐normality of the test results.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3