Intentional deep overfit learning for patient‐specific dose predictions in adaptive radiotherapy

Author:

Maniscalco Austen1,Liang Xiao1,Lin Mu‐Han1,Jiang Steve1,Nguyen Dan1

Affiliation:

1. Medical Artificial Intelligence and Automation Laboratory Department of Radiation Oncology University of Texas Southwestern Medical Center Dallas Texas USA

Abstract

AbstractBackgroundThe framework of adaptive radiation therapy (ART) was crafted to address the underlying sources of intra‐patient variation that were observed throughout numerous patients' radiation sessions. ART seeks to minimize the consequential dosimetric uncertainty resulting from this daily variation, commonly through treatment planning re‐optimization. Re‐optimization typically consists of manual evaluation and modification of previously utilized optimization criteria. Ideally, frequent treatment plan adaptation through re‐optimization on each day's computed tomography (CT) scan may improve dosimetric accuracy and minimize dose delivered to organs at risk (OARs) as the planning target volume (PTV) changes throughout the course of treatment.PurposeRe‐optimization in its current form is time‐consuming and inefficient. In response to this ART bottleneck, we propose a deep learning based adaptive dose prediction model that utilizes a head and neck (H&N) patient's initial planning data to fine‐tune a previously trained population model towards a patient‐specific model. Our fine‐tuned, patient‐specific (FT‐PS) model, which is trained using the intentional deep overfit learning (IDOL) method, may enable clinicians and treatment planners to rapidly evaluate relevant dosimetric changes daily and re‐optimize accordingly.MethodsAn adaptive population (AP) model was trained using adaptive data from 33 patients. Separately, 10 patients were selected for training FT‐PS models. The previously trained AP model was utilized as the base model weights prior to re‐initializing model training for each FT‐PS model. Ten FT‐PS models were separately trained by fine‐tuning the previous model weights based on each respective patient's initial treatment plan. From these 10 patients, 26 ART treatment plans were withheld from training as the test dataset for retrospective evaluation of dose prediction performance between the AP and FT‐PS models. Each AP and FT‐PS dose prediction was compared against the ground truth dose distribution as originally generated during the patient's course of treatment. Mean absolute percent error (MAPE) evaluated the dose differences between a model's prediction and the ground truth.ResultsMAPE was calculated within the 10% isodose volume region of interest for each of the AP and FT‐PS models dose predictions and averaged across all test adaptive sessions, yielding 5.759% and 3.747% respectively. MAPE differences were compared between AP and FT‐PS models across each test session in a test of statistical significance. The differences were statistically significant in a paired t‐test with two‐tailed p‐value equal to and 95% confidence interval (CI) equal to [−2.483, −1.542]. Furthermore, MAPE was calculated using each individually segmented structure as an ROI. Nineteen of 24 structures demonstrated statistically significant differences between the AP and FT‐PS models.ConclusionWe utilized the IDOL method to fine‐tune a population‐based dose prediction model into an adaptive, patient‐specific model. The averaged MAPE across the test dataset was 5.759% for the population‐based model versus 3.747% for the fine‐tuned, patient‐specific model, and the difference in MAPE between models was found to be statistically significant. Our work demonstrates the feasibility of patient‐specific models in adaptive radiotherapy, and offers unique clinical benefit by utilizing initial planning data that contains the physician's treatment intent.

Funder

National Institutes of Health

Publisher

Wiley

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3