New Insights into the Spread of MRS‐Based Water T2 Values Observed in Highly Fatty Replaced Muscles

Author:

Reyngoudt Harmen1ORCID,Baudin Pierre‐Yves1,Carlier Pierre G.2,Lopez Kolkovsky Alfredo L.1,de Almeida Araujo Ericky Caldas1ORCID,Marty Benjamin1ORCID

Affiliation:

1. NMR Laboratory, Neuromuscular Investigation Center Institute of Myology Paris France

2. Université Paris Saclay CEA, Service Hospitalier Frédéric Joliot Orsay France

Abstract

BackgroundThe reference standard for assessing water T2 (T2,H2O) at high fat fraction (FF) is 1H MRS. T2,H2O (T2,H2O,MRS) dependence on FF (FFMRS) has recently been demonstrated in muscle at high FF (i.e. ≥60%).PurposeTo investigate the relationship between T2,H2O,MRS and FFMRS in the thigh/leg muscles of patients with neuromuscular diseases and to compare with quantitative MRI.Study TypeRetrospective case–control study.PopulationA total of 151 patients with neuromuscular disorders (mean age ± standard deviation = 52.5 ± 22.6 years, 54% male), 44 healthy volunteers (26.5 ± 13.0 years, 57% male).Field Strength/SequenceA 3‐T; single‐voxel stimulated echo acquisition mode (STEAM) MRS, multispin echo (MSE) imaging (for T2 mapping, T2,H2O,MRI), three‐point Dixon imaging (for FFMRI and mapping).AssessmentMono‐exponential and bi‐exponential models were fitted to water T2 decay curves to extract T2,H2O,MRS and FFMRS. Water resonance full‐width‐at‐half‐maximum (FWHM) and B0 spread (∆B0) values were calculated. T2,H2O,MRI (mean), FFMRI (mean, kurtosis, and skewness), and (mean) values were estimated in the MRS voxel.Statistical TestsMann–Whitney U tests, Kruskal–Wallis tests. A P‐value <0.05 was considered statistically significant.ResultsNormal T2,H2O,MRS threshold was defined as the 90th percentile in healthy controls: 30.3 msec. T2,H2O,MRS was significantly higher in all patients with FFMRS < 60% compared to healthy controls. We discovered two subgroups in patients with FFMRS ≥ 60%: one with T2,H2O,MRS ≥ 30.3 msec and one with T2,H2O,MRS < 30.3 msec including abnormally low T2,H2O,MRS. The latter subgroup had significantly higher water resonance FWHM, ∆B0, FFMRI kurtosis, and skewness values but nonsignificantly different (P = 1.00) and long T2,H2O,MRS component and its fraction (P > 0.11) based on the bi‐exponential analysis.Data ConclusionThe findings suggest that the cause for (abnormally) T2,H2O,MRS at high FFMRS is biophysical, due to differences in susceptibility between muscle and fat (increased FWHM and ∆B0), rather than pathophysiological such as compartmentation changes, which would be reflected by the bi‐exponential analysis.Evidence Level3Technical EfficacyStage 3

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3