Dynamic Contrast‐Enhanced MRI in Abdominal Aortic Aneurysms as a Potential Marker for Disease Progression

Author:

Zhou Ang12ORCID,Leach Joseph R.12,Zhu Chengcheng3ORCID,Dong Huiming12,Jiang Fei4,Lee Yoo Jin1,Iannuzzi James25,Gasper Warren25,Saloner David12,Hope Michael D.12,Mitsouras Dimitrios12

Affiliation:

1. Department of Radiology and Biomedical Imaging University of California San Francisco San Francisco California USA

2. San Francisco Veterans Affairs Medical Center San Francisco California USA

3. Department of Radiology University of Washington Seattle Washington USA

4. Department of Biostatistics University of California San Francisco San Francisco California USA

5. Department of Surgery University of California San Francisco San Francisco California USA

Abstract

BackgroundAbdominal aortic aneurysms (AAAs) may rupture before reaching maximum diameter (Dmax) thresholds for repair. Aortic wall microvasculature has been associated with elastin content and rupture sites in specimens, but its relation to progression is unknown.PurposeTo investigate whether dynamic contrast‐enhanced (DCE) MRI of AAA is associated with Dmax or growth.Study TypeProspective.PopulationA total of 27 male patients with infrarenal AAA (mean age ± standard deviation = 75 ± 5 years) under surveillance with DCE MRI and 2 years of prior follow‐up intervals with computed tomography (CT) or MRI.Field Strength/SequenceA 3‐T, dynamic three‐dimensional (3D) fast gradient‐echo stack‐of‐stars volumetric interpolated breath‐hold examination (Star‐VIBE).AssessmentWall voxels were manually segmented in two consecutive slices at the level of Dmax. We measured slope to 1‐minute and area under the curve (AUC) to 1 minute and 4 minutes of the signal intensity change postcontrast relative to that precontrast arrival, and, Ktrans, a measure of microvascular permeability, using the Patlak model. These were averaged over all wall voxels for association to Dmax and growth rate, and, over left/right and anterior/posterior quadrants for testing circumferential homogeneity. Dmax was measured orthogonal to the aortic centerline and growth rate was calculated by linear fit of Dmax measurements.Statistical TestsPearson correlation and linear mixed effects models. A P value <0.05 was considered statistically significant.ResultsIn 44 DCE MRIs, mean Dmax was 45 ± 7 mm and growth rate in 1.5 ± 0.4 years of prior follow‐up was 1.7 ± 1.2 mm per year. DCE measurements correlated with each other (Pearson r = 0.39–0.99) and significantly differed between anterior/posterior versus left/right quadrants. DCE measurements were not significantly associated with Dmax (P = 0.084, 0.289, 0.054 and 0.255 for slope, AUC at 1 minute and 4 minutes, and Ktrans, respectively). Slope and 4 minutes AUC significantly associated with growth rate after controlling for Dmax.ConclusionContrast uptake may be increased in lateral aspects of the AAA. Contrast enhancement 1‐minute slope and 4‐minutes AUC may be associated with a period of recent AAA growth that is independent of Dmax.Evidence Level3.Technical EfficacyStage 2.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3